CVEdetails.com the ultimate security vulnerability data source
(e.g.: CVE-2009-1234 or 2010-1234 or 20101234)
Log In   Register
Vulnerability Feeds & WidgetsNew   www.itsecdb.com  

Lenovo : Security Vulnerabilities (Denial Of Service)

Press ESC to close
# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
1 CVE-2020-8357 276 DoS 2021-03-09 2021-03-12
2.1
None Local Low Not required None None Partial
A denial of service vulnerability was reported in Lenovo PCManager, prior to version 3.0.200.2042, that could allow configuration files to be written to non-standard locations.
2 CVE-2020-8346 276 DoS 2020-09-15 2020-09-21
2.1
None Local Low Not required None None Partial
A denial of service vulnerability was reported in the Lenovo Vantage component called Lenovo System Interface Foundation prior to version 1.1.19.5 that could allow configuration files to be written to non-standard locations.
3 CVE-2019-6183 DoS 2019-12-10 2020-08-24
7.8
None Remote Low Not required None None Complete
A denial of service vulnerability has been reported in Lenovo Energy Management Driver for Windows 10 versions prior to 15.11.29.7 that could cause systems to experience a blue screen error. Lenovo Energy Management is a client utility. Lenovo XClarity Energy Manager is not affected.
4 CVE-2019-6175 DoS 2019-09-26 2020-08-24
7.8
None Remote Low Not required None None Complete
A denial of service vulnerability was reported in Lenovo System Update versions prior to 5.07.0088 that could allow configuration files to be written to non-standard locations.
5 CVE-2017-3740 DoS 2017-06-04 2019-10-03
4.9
None Local Low Not required None None Complete
In Lenovo Active Protection System before 1.82.0.14, an attacker with local privileges could send commands to the system's embedded controller, which could cause a denial of service attack on the system or the ability to alter hardware functionality.
6 CVE-2016-8226 19 DoS 2017-01-26 2017-02-01
6.8
None Remote Low ??? None None Complete
The BIOS in Lenovo System X M5, M6, and X6 systems allows administrators to cause a denial of service via updating a UEFI data structure.
7 CVE-2016-8106 20 DoS 2017-01-09 2017-07-27
4.3
None Remote Medium Not required None None Partial
A Denial of Service in Intel Ethernet Controller's X710/XL710 with Non-Volatile Memory Images before version 5.05 allows a remote attacker to stop the controller from processing network traffic working under certain network use conditions.
Total number of vulnerabilities : 7   Page : 1 (This Page)
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.