1 CVE-2019-13921 287 2019-10-10 2019-10-15
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the service provided by the software. At the time of advisory publication no public exploitation of this security vulnerability was known.
2 CVE-2019-12265 399 +Info 2019-08-09 2019-09-10
5.0
None Remote Low Not required Partial None None
Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.
3 CVE-2019-12259 476 2019-08-09 2019-09-10
5.0
None Remote Low Not required None None Partial
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing.
4 CVE-2019-12258 384 2019-08-09 2019-09-10
5.0
None Remote Low Not required None None Partial
Wind River VxWorks 6.6 through vx7 has Session Fixation in the TCP component. This is a IPNET security vulnerability: DoS of TCP connection via malformed TCP options.
5 CVE-2019-12257 119 Overflow 2019-08-09 2019-08-16
5.8
None Local Network Low Not required Partial Partial Partial
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc.
6 CVE-2019-10953 400 2019-04-17 2019-05-22
5.0
None Remote Low Not required None None Partial
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
7 CVE-2019-10943 284 2019-08-13 2019-10-09
5.0
None Remote Low Not required None Partial None
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7-1200 CPU family (All versions >= V4.0), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-PLCSIM Advanced (All versions). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device. No public exploitation of the vulnerability was known at the time of advisory publication.
8 CVE-2019-10942 20 2019-08-13 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SCALANCE X-200 (All versions), SCALANCE X-200IRT (All versions), SCALANCE X-200RNA (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
9 CVE-2019-10936 400 2019-10-10 2019-10-15
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.2.3), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. F) (All versions), SIMATIC S7-1500 CPU family (incl. F) (All versions < V2.0), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400 V6 (incl F) and below (All versions), SIMATIC S7-400H V6 (All versions < V6.0.9), SIMATIC S7-410 V8 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions), SINAMICS G150 (Control Unit) (All versions), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S150 (Control Unit) (All versions), SINAMICS SL150 V4.7 (Control Unit) (All versions), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
10 CVE-2019-10931 20 DoS 2019-07-11 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions), DIGSI 5 engineering software (All versions < V7.90). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
11 CVE-2019-10925 264 2019-06-12 2019-10-09
5.5
None Remote Low Single system None Partial Partial
A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
12 CVE-2019-10923 400 2019-10-10 2019-10-15
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT (All versions < V5.2.1), SIMATIC ET 200M (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (All versions), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 (Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions < V4.7 HF29), SINAMICS G150 (Control Unit) (All versions < V4.8), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit and CBE20) (All versions < V4.7 HF34), SINAMICS S150 (Control Unit) (All versions < V4.8), SINAMICS SL150 V4.7 (Control Unit) (All versions), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
13 CVE-2019-10921 255 2019-05-14 2019-05-30
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in LOGO!8 BM (All versions). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known
14 CVE-2019-10920 798 2019-05-14 2019-05-30
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in LOGO!8 BM (All versions). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
15 CVE-2019-6578 20 DoS 2019-05-14 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28). A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
16 CVE-2019-6576 310 2019-05-14 2019-05-22
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
17 CVE-2019-6574 284 2019-05-14 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
18 CVE-2019-6568 20 2019-04-17 2019-10-10
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in CP1604 (All versions), CP1616 (All versions), SIMATIC CP343-1 Advanced (All versions), SIMATIC CP443-1 (All versions), SIMATIC CP443-1 Advanced (All versions), SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 SP Open Controller CPU 1515SP PC (All versions < V2.1.6), SIMATIC ET 200 SP Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC RF181-EIP (All versions), SIMATIC RF182C (All versions), SIMATIC RF185C (All versions < V1.1.0), SIMATIC RF186C (All versions < V1.1.0), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (All versions < V2.6.1), SIMATIC S7-1500 Software Controller (All versions < V2.7), SIMATIC S7-300 CPU family (All versions < V3.X.16), SIMATIC S7-400 PN (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V2.0 SP1 UPD1), SIMATIC Teleservice Adapter IE Advanced (All versions), SIMATIC Teleservice Adapter IE Basic (All versions), SIMATIC Teleservice Adapter IE Standard (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMATIC WinCC Runtime Advanced (All versions), SIMOCODE pro V EIP (All versions), SIMOCODE pro V PN (All versions), SINAMICS G130 V4.6 (Control Unit) (All versions), SINAMICS G130 V4.7 (Control Unit) (All versions), SINAMICS G130 V4.7 SP1 (Control Unit) (All versions), SINAMICS G130 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS G130 V5.1 (Control Unit) (All versions), SINAMICS G130 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS G150 V4.6 (Control Unit) (All versions), SINAMICS G150 V4.7 (Control Unit) (All versions), SINAMICS G150 V4.7 SP1 (Control Unit) (All versions), SINAMICS G150 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS G150 V5.1 (Control Unit) (All versions), SINAMICS G150 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS S120 V4.6 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S120 V4.7 SP1 (Control Unit) (All versions), SINAMICS S120 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS S120 V5.1 (Control Unit) (All versions), SINAMICS S120 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS S150 V4.6 (Control Unit) (All versions), SINAMICS S150 V4.7 (Control Unit) (All versions), SINAMICS S150 V4.7 SP1 (Control Unit) (All versions), SINAMICS S150 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS S150 V5.1 (Control Unit) (All versions), SINAMICS S150 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS S210 V5.1 (Control Unit) (All versions), SINAMICS S210 V5.1 SP1 (Control Unit) (All versions), SITOP Manager (All versions), SITOP PSU8600 (All versions), SITOP UPS1600 (All versions), TIM 1531 IRC (All versions). The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
19 CVE-2018-16890 125 Overflow 2019-02-06 2019-07-23
5.0
None Remote Low Not required None None Partial
libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.
20 CVE-2018-13815 400 2018-12-13 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
21 CVE-2018-13813 601 2018-12-13 2019-10-09
5.8
None Remote Medium Not required Partial Partial None
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
22 CVE-2018-13812 22 Dir. Trav. 2018-12-13 2019-10-09
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
23 CVE-2018-11456 2018-08-07 2019-10-09
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
24 CVE-2018-4850 2018-05-16 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SIMATIC S7-400 (incl. F) CPU hardware version 4.0 and below (All versions), SIMATIC S7-400 (incl. F) CPU hardware version 5.0 (All firmware versions < V5.2), SIMATIC S7-400H CPU hardware version 4.5 and below (All versions). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart.
25 CVE-2018-4840 306 2018-03-08 2019-10-09
5.0
None Remote Low Not required None Partial None
A vulnerability has been identified in Siemens DIGSI 4 (All versions < V4.92), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 104 variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
26 CVE-2018-4838 306 2018-03-08 2019-10-02
5.0
None Remote Low Not required None Partial None
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
27 CVE-2018-4833 20 Exec Code +Priv 2018-06-14 2019-10-10
5.8
None Local Network Low Not required Partial Partial Partial
A vulnerability has been identified in RFID 181-EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 (All versions < V5.2.3), SCALANCE X-200IRT (All versions < V5.4.1), SCALANCE X-200RNA (All versions < V3.2.6), SCALANCE X-300 (All versions), SCALANCE X408 (All versions), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client?s DHCP request.
28 CVE-2018-4832 20 2018-04-24 2018-10-10
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions < V8.2 SP1), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < SIMATIC BATCH V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < SIMATIC BATCH V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 SP1), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC-Software (All versions), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions < V8.2 SP1), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd4). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality.
29 CVE-2017-12737 200 +Info 2017-11-15 2017-11-30
5.0
None Remote Low Not required Partial None None
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.
30 CVE-2017-12735 2017-08-30 2019-10-09
5.8
None Remote Medium Not required Partial Partial None
A vulnerability has been identified in Siemens LOGO! devices. An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic.
31 CVE-2017-12734 200 +Info 2017-08-30 2019-10-09
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in Siemens LOGO! devices before V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.
32 CVE-2017-9941 2017-08-07 2019-10-09
5.8
None Remote Medium Not required Partial Partial None
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.
33 CVE-2017-9940 269 2017-08-07 2019-10-09
5.5
None Remote Low Single system Partial Partial None
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network.
34 CVE-2017-9938 20 2017-08-07 2017-11-21
5.0
None Remote Low Not required None None Partial
A vulnerability was discovered in Siemens SIMATIC Logon (All versions before V1.6) that could allow specially crafted packets sent to the SIMATIC Logon Remote Access service on port 16389/tcp to cause a Denial-of-Service condition. The service restarts automatically.
35 CVE-2017-6873 2017-08-07 2019-10-09
5.8
None Remote Medium Not required Partial Partial None
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
36 CVE-2017-6870 2017-08-07 2019-10-09
5.8
None Remote Medium Not required Partial Partial None
A vulnerability was discovered in Siemens SIMATIC WinCC [email protected] for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.
37 CVE-2017-2685 200 +Info 2017-03-01 2019-10-09
5.8
None Remote Medium Not required Partial Partial None
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
38 CVE-2016-9160 254 2016-12-16 2017-07-26
5.8
None Remote Medium Not required Partial None Partial
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions.
39 CVE-2016-9155 284 2016-11-22 2016-12-22
5.0
None Remote Low Not required Partial None None
The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances.
40 CVE-2016-9154 332 2016-12-23 2019-10-09
5.0
None Remote Low Not required Partial None None
Siemens Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 for Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D (All firmware versions < V6.00.046) and Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 for Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U (All firmware versions < V6.00.046) use a pseudo random number generator with insufficient entropy to generate certificates for HTTPS, potentially allowing remote attackers to reconstruct the corresponding private key.
41 CVE-2016-8672 200 +Info 2016-11-23 2017-03-16
5.0
None Remote Low Not required Partial None None
The integrated web server on Siemens SIMATIC CP 343-1 Advanced prior to version 3.0.53, SIMATIC CP 443-1 Advanced prior to version 3.2.17, SIMATIC S7-300 CPU, and SIMATIC S7-400 CPU devices does not set the secure flag for unspecified cookies in an https session, which makes it easier for remote attackers to capture these cookies by intercepting their transmission within an http session.
42 CVE-2016-8563 20 DoS 2016-10-13 2017-07-28
5.0
None Remote Low Not required None None Partial
Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to cause a denial of service (ALM service outage) via crafted packets to TCP port 4410.
43 CVE-2016-5874 20 DoS 2016-07-22 2016-11-28
5.0
None Remote Low Not required None None Partial
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets.
44 CVE-2016-5744 200 +Info 2016-07-22 2016-11-28
5.0
None Remote Low Not required Partial None None
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
45 CVE-2016-4785 200 +Info 2016-05-30 2018-03-22
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.
46 CVE-2016-4784 200 +Info 2016-05-30 2018-03-22
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
47 CVE-2016-3963 DoS 2016-04-08 2018-05-25
5.0
None Remote Low Not required None None Partial
Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443.
48 CVE-2016-2201 20 Bypass 2016-02-08 2016-12-06
5.0
None Remote Low Not required None Partial None
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102.
49 CVE-2015-5717 310 +Info 2015-08-31 2015-11-04
5.8
None Remote Medium Not required Partial Partial None
The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
50 CVE-2015-3610 310 +Info 2015-05-07 2015-05-07
5.4
None Local Network Medium Not required Partial Partial Partial
The Siemens HomeControl for Room Automation application before 2.0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information or modify data via a crafted certificate.
Total number of vulnerabilities : 78   Page : 1 (This Page)2
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.