1 CVE-2018-11448 79 Exec Code XSS 2018-06-26 2018-08-24
3.5
None Remote Medium Single system None Partial None
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
2 CVE-2018-4842 79 Exec Code XSS 2018-06-14 2018-08-11
3.5
None Remote Medium Single system None Partial None
A vulnerability has been identified in SCALANCE X-200 IRT (All versions < V5.4.1), SCALANCE X300 (All versions). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site.
3 CVE-2018-4839 285 2018-03-08 2018-03-29
3.5
None Remote Medium Single system Partial None None
A vulnerability has been identified in Siemens DIGSI 4 (All versions < V4.92), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77), SIPROTEC Compact 7SJ66 (All versions < V4.30), Other SIPROTEC Compact relays (All versions), Other SIPROTEC 4 relays (All versions). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
4 CVE-2017-6864 79 XSS 2017-03-28 2017-07-11
3.5
None Remote Medium Single system None Partial None
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks.
5 CVE-2016-8562 20 DoS 2016-11-18 2016-12-21
3.5
None Remote Medium Single system None None Partial
Siemens SIMATIC CP 1543-1 before 2.0.28, when SNMPv3 write access or SNMPv1 is enabled, allows remote authenticated users to cause a denial of service by modifying SNMP variables.
6 CVE-2016-3155 200 +Info 2016-03-18 2016-12-02
3.6
None Local Low Not required Partial Partial None
Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors.
7 CVE-2015-7836 200 +Info 2015-10-28 2017-09-14
3.3
None Local Network Low Not required Partial None None
Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame.
8 CVE-2013-0672 79 XSS 2013-03-21 2013-03-22
3.5
None Remote Medium Single system None Partial None
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
9 CVE-2012-4691 399 DoS 2012-12-18 2013-01-29
3.3
None Local Network Low Not required None None Partial
Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.
10 CVE-2004-2626 2004-12-31 2017-07-19
3.7
User Local High Not required Partial Partial Partial
GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message.
Total number of vulnerabilities : 10   Page : 1 (This Page)
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.