Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
Max CVSS
9.8
EPSS Score
0.04%
Published
2024-04-02
Updated
2024-04-08
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
Max CVSS
9.8
EPSS Score
0.04%
Published
2024-04-02
Updated
2024-04-08
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.
Max CVSS
9.8
EPSS Score
0.04%
Published
2024-03-12
Updated
2024-03-21
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.
Max CVSS
9.8
EPSS Score
0.04%
Published
2024-03-12
Updated
2024-03-21
Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.
Max CVSS
9.8
EPSS Score
0.15%
Published
2024-02-05
Updated
2024-02-14
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-17
Updated
2024-04-17
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-17
Updated
2024-04-17
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-17
Updated
2024-04-17
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-17
Updated
2024-04-17
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-17
Updated
2024-04-17
A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-04-16
Updated
2024-04-17
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-28
Updated
2024-04-11
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-28
Updated
2024-04-11
A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-27
Updated
2024-04-11
A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-27
Updated
2024-04-11
A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-27
Updated
2024-04-11
A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-27
Updated
2024-04-11
A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Max CVSS
9.0
EPSS Score
0.05%
Published
2024-03-27
Updated
2024-04-11
524 vulnerabilities found