Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities.
Max CVSS
9.8
EPSS Score
0.21%
Published
2022-04-01
Updated
2022-04-08
Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.
Max CVSS
9.8
EPSS Score
0.21%
Published
2022-04-01
Updated
2022-04-09
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
Max CVSS
9.8
EPSS Score
0.37%
Published
2018-09-26
Updated
2018-11-21
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.
Max CVSS
9.8
EPSS Score
1.02%
Published
2018-09-26
Updated
2019-10-09
In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountability that properly implemented encryption conveys.
Max CVSS
9.8
EPSS Score
0.16%
Published
2018-03-28
Updated
2019-10-09
Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash.
Max CVSS
9.8
EPSS Score
4.12%
Published
2018-03-26
Updated
2019-10-09
Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code.
Max CVSS
9.8
EPSS Score
0.78%
Published
2018-03-26
Updated
2019-10-09
Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code
Max CVSS
9.8
EPSS Score
0.78%
Published
2018-03-26
Updated
2019-10-09
In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code.
Max CVSS
9.8
EPSS Score
0.33%
Published
2018-03-28
Updated
2019-10-09
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.
Max CVSS
9.1
EPSS Score
0.23%
Published
2018-04-24
Updated
2019-10-09
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
Max CVSS
10.0
EPSS Score
0.66%
Published
2017-04-10
Updated
2017-04-14
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.
Max CVSS
9.3
EPSS Score
0.20%
Published
2013-10-05
Updated
2013-10-07
12 vulnerabilities found