CVEdetails.com the ultimate security vulnerability data source
(e.g.: CVE-2009-1234 or 2010-1234 or 20101234)
Log In   Register
Vulnerability Feeds & WidgetsNew   www.itsecdb.com  

Security Vulnerabilities (CVSS score between 5 and 6.99)

Press ESC to close
# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
2001 CVE-2019-6644 285 2019-09-04 2019-09-09
6.8
None Remote Medium Not required Partial Partial Partial
Similar to the issue identified in CVE-2018-12120, on versions 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.2, and 12.1.0-12.1.4 BIG-IP will bind a debug nodejs process to all interfaces when invoked. This may expose the process to unauthorized users if the plugin is left in debug mode and the port is accessible.
2002 CVE-2019-6643 20 2019-09-04 2019-10-09
5.0
None Remote Low Not required None None Partial
On versions 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.2, 12.1.0-12.1.4.1, and 11.5.2-11.6.4, an attacker sending specifically crafted DHCPv6 requests through a BIG-IP virtual server configured with a DHCPv6 profile may be able to cause the TMM process to produce a core file.
2003 CVE-2019-6640 200 +Info 2019-07-03 2019-07-10
5.0
None Remote Low Not required Partial None None
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.1-11.5.8, SNMP exposes sensitive configuration objects over insecure transmission channels. This issue is exposed when a passphrase is inserted into various profile types and accessed using SNMPv2.
2004 CVE-2019-6630 20 2019-07-03 2019-07-10
5.0
None Remote Low Not required None None Partial
On F5 SSL Orchestrator 14.1.0-14.1.0.5 and 14.0.0-14.0.0.4, undisclosed traffic flow may cause TMM to restart under certain circumstances.
2005 CVE-2019-6629 20 2019-07-03 2019-10-09
5.0
None Remote Low Not required None None Partial
On BIG-IP 14.1.0-14.1.0.5, undisclosed SSL traffic to a virtual server configured with a Client SSL profile may cause TMM to fail and restart. The Client SSL profile must have session tickets enabled and use DHE cipher suites to be affected. This only impacts the data plane, there is no impact to the control plane.
2006 CVE-2019-6628 20 2019-07-03 2019-07-08
5.0
None Remote Low Not required None None Partial
On BIG-IP PEM 14.1.0-14.1.0.5 and 14.0.0-14.0.0.4, under certain conditions, the TMM process may terminate and restart while processing BIG-IP PEM traffic with the OpenVPN classifier.
2007 CVE-2019-6624 20 2019-07-02 2019-07-03
5.0
None Remote Low Not required None None Partial
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.1.4, and 12.1.0-12.1.4, an undisclosed traffic pattern sent to a BIG-IP UDP virtual server may lead to a denial-of-service (DoS).
2008 CVE-2019-6623 20 2019-07-02 2019-07-05
5.0
None Remote Low Not required None None Partial
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.1.4, and 12.1.0-12.1.4, undisclosed traffic sent to BIG-IP iSession virtual server may cause the Traffic Management Microkernel (TMM) to restart, resulting in a Denial-of-Service (DoS).
2009 CVE-2019-6622 77 2019-07-02 2019-07-03
6.5
None Remote Low Single system Partial Partial Partial
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.5, 13.0.0-13.1.1.4, 12.1.0-12.1.4.1, and 11.5.1-11.6.4, an undisclosed iControl REST worker is vulnerable to command injection by an administrator or resource administrator user. This attack is only exploitable on multi-bladed systems.
2010 CVE-2019-6621 77 2019-07-02 2019-10-09
6.5
None Remote Low Single system Partial Partial Partial
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.5, 13.0.0-13.1.1.4, 12.1.0-12.1.4.1, 11.6.1-11.6.3.4, and 11.5.1-11.5.8 and BIG-IQ 6.0.0-6.1.0 and 5.1.0-5.4.0, an undisclosed iControl REST worker is vulnerable to command injection by an admin/resource admin user. This issue impacts both iControl REST and tmsh implementations.
2011 CVE-2019-6620 77 2019-07-02 2019-07-03
6.5
None Remote Low Single system Partial Partial Partial
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.5, 13.0.0-13.1.1.4, 12.1.0-12.1.4.1, and 11.5.1-11.6.4 and BIG-IQ 6.0.0-6.1.0 and 5.1.0-5.4.0, an undisclosed iControl REST worker vulnerable to command injection for an Administrator user.
2012 CVE-2019-6619 20 2019-05-03 2019-05-08
5.0
None Remote Low Not required None None Partial
On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, and 12.1.0-12.1.4, the Traffic Management Microkernel (TMM) may restart when a virtual server has an HTTP/2 profile with Application Layer Protocol Negotiation (ALPN) enabled and it processes traffic where the ALPN extension size is zero.
2013 CVE-2019-6617 275 2019-05-03 2019-05-24
5.5
None Remote Low Single system None Partial Partial
On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, a user with the Resource Administrator role is able to overwrite sensitive low-level files (such as /etc/passwd) using SFTP to modify user permissions, without Advanced Shell access. This is contrary to our definition for the Resource Administrator (RA) role restrictions.
2014 CVE-2019-6616 284 Bypass 2019-05-03 2019-05-13
6.5
None Remote Low Single system Partial Partial Partial
On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, administrative users with TMSH access can overwrite critical system files on BIG-IP which can result in bypass of whitelist / blacklist restrictions enforced by appliance mode.
2015 CVE-2019-6615 264 Bypass 2019-05-03 2019-05-08
6.5
None Remote Low Single system Partial Partial Partial
On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, Administrator and Resource Administrator roles might exploit TMSH access to bypass Appliance Mode restrictions on BIG-IP systems.
2016 CVE-2019-6614 264 Bypass 2019-05-03 2019-05-13
5.5
None Remote Low Single system None Partial Partial
On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, and 12.1.0-12.1.4, internal methods used to prevent arbitrary file overwrites in Appliance Mode were not fully effective. An authenticated attacker with a high privilege level may be able to bypass protections implemented in appliance mode to overwrite arbitrary system files.
2017 CVE-2019-6613 200 +Info 2019-05-03 2019-05-08
5.0
None Remote Low Not required Partial None None
On BIG-IP 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, SNMP may expose sensitive configuration objects over insecure transmission channels. This issue is exposed when a passphrase is used with various profile types and is accessed using SNMPv2.
2018 CVE-2019-6612 20 2019-05-03 2019-05-13
5.0
None Remote Low Not required None None Partial
On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, DNS query TCP connections that are aborted before receiving a response from a DNS cache may cause TMM to restart.
2019 CVE-2019-6611 20 2019-05-03 2019-05-08
5.0
None Remote Low Not required None None Partial
When BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8 are processing certain rare data sequences occurring in PPTP VPN traffic, the BIG-IP system may execute incorrect logic. The TMM may restart and produce a core file as a result of this condition. The BIG-IP system provisioned with the CGNAT module and configured with a virtual server using a PPTP profile is exposed to this vulnerability.
2020 CVE-2019-6609 255 2019-04-15 2019-05-06
5.0
None Remote Low Not required Partial None None
Platform dependent weakness. This issue only impacts iSeries platforms. On these platforms, in BIG-IP (LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, FPS, GTM, Link Controller, PEM, WebAccelerator) versions 14.0.0-14.1.0.1, 13.0.0-13.1.1.3, and 12.1.1 HF2-12.1.4, the secureKeyCapable attribute was not set which causes secure vault to not use the F5 hardware support to store the unit key. Instead the unit key is stored in plaintext on disk as would be the case for Z100 systems. Additionally this causes the unit key to be stored in UCS files taken on these platforms.
2021 CVE-2019-6607 352 Exec Code XSS CSRF 2019-03-28 2019-04-05
6.0
None Remote Medium Single system Partial Partial Partial
On BIG-IP ASM 11.5.1-11.5.8, 11.6.1-11.6.3, 12.1.0-12.1.3, 13.0.0-13.1.1.3, and 14.0.0-14.0.0.2, there is a stored cross-site scripting vulnerability in an ASM violation viewed in the Configuration utility. In the worst case, an attacker can store a CSRF which results in code execution as the admin user.
2022 CVE-2019-6605 20 DoS 2019-03-28 2019-04-05
5.0
None Remote Low Not required None None Partial
On BIG-IP 11.5.1-11.5.8, 11.6.1-11.6.3, and 12.0.x, an undisclosed sequence of packets received by an SSL virtual server and processed by an associated Client SSL or Server SSL profile may cause a denial of service.
2023 CVE-2019-6603 20 2019-03-28 2019-04-03
5.0
None Remote Low Not required None None Partial
In BIG-IP 11.5.1-11.5.8, 11.6.1-11.6.3, 12.1.0-12.1.3, and 13.0.0-13.0.1, malformed TCP packets sent to a self IP address or a FastL4 virtual server may cause an interruption of service. The control plane is not exposed to this issue. This issue impacts the data plane virtual servers and self IPs.
2024 CVE-2019-6602 254 2019-03-28 2019-04-03
5.0
None Remote Low Not required Partial None None
In BIG-IP 11.5.1-11.5.8 and 11.6.1-11.6.3, the Configuration Utility login page may not follow best security practices when handling a malicious request.
2025 CVE-2019-6584 284 2019-06-12 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.
2026 CVE-2019-6582 264 2019-06-12 2019-10-09
5.5
None Remote Low Single system None Partial Partial
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known.
2027 CVE-2019-6581 264 2019-06-12 2019-10-09
6.5
None Remote Low Single system Partial Partial Partial
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
2028 CVE-2019-6580 285 2019-06-12 2019-10-09
6.5
None Remote Low Single system Partial Partial Partial
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
2029 CVE-2019-6578 20 DoS 2019-05-14 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28). A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
2030 CVE-2019-6576 310 2019-05-14 2019-05-22
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
2031 CVE-2019-6574 284 2019-05-14 2019-10-09
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
2032 CVE-2019-6572 264 2019-05-14 2019-05-22
6.4
None Remote Low Not required Partial Partial None
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
2033 CVE-2019-6569 20 2019-03-26 2019-06-12
6.4
None Remote Low Not required Partial None Partial
A vulnerability has been identified in Scalance X-200 (All versions <V5.2.4), Scalance X-300 (All versions), Scalance XP/XC/XF-200 (All versions <V4.1). The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker might use this behaviour to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behaviour. The security vulnerability could be exploited by an attacker with network access to the traffic-receiving network. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the confidentiality and availability of the traffic-generating network. At the time of advisory publication no public exploitation of this security vulnerability was known.
2034 CVE-2019-6568 20 2019-04-17 2019-10-10
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in CP1604 (All versions), CP1616 (All versions), SIMATIC CP343-1 Advanced (All versions), SIMATIC CP443-1 (All versions), SIMATIC CP443-1 Advanced (All versions), SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 SP Open Controller CPU 1515SP PC (All versions < V2.1.6), SIMATIC ET 200 SP Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC RF181-EIP (All versions), SIMATIC RF182C (All versions), SIMATIC RF185C (All versions < V1.1.0), SIMATIC RF186C (All versions < V1.1.0), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (All versions < V2.6.1), SIMATIC S7-1500 Software Controller (All versions < V2.7), SIMATIC S7-300 CPU family (All versions < V3.X.16), SIMATIC S7-400 PN (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V2.0 SP1 UPD1), SIMATIC Teleservice Adapter IE Advanced (All versions), SIMATIC Teleservice Adapter IE Basic (All versions), SIMATIC Teleservice Adapter IE Standard (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMATIC WinCC Runtime Advanced (All versions), SIMOCODE pro V EIP (All versions), SIMOCODE pro V PN (All versions), SINAMICS G130 V4.6 (Control Unit) (All versions), SINAMICS G130 V4.7 (Control Unit) (All versions), SINAMICS G130 V4.7 SP1 (Control Unit) (All versions), SINAMICS G130 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS G130 V5.1 (Control Unit) (All versions), SINAMICS G130 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS G150 V4.6 (Control Unit) (All versions), SINAMICS G150 V4.7 (Control Unit) (All versions), SINAMICS G150 V4.7 SP1 (Control Unit) (All versions), SINAMICS G150 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS G150 V5.1 (Control Unit) (All versions), SINAMICS G150 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS S120 V4.6 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S120 V4.7 SP1 (Control Unit) (All versions), SINAMICS S120 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS S120 V5.1 (Control Unit) (All versions), SINAMICS S120 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS S150 V4.6 (Control Unit) (All versions), SINAMICS S150 V4.7 (Control Unit) (All versions), SINAMICS S150 V4.7 SP1 (Control Unit) (All versions), SINAMICS S150 V4.8 (Control Unit) (All versions < V4.8 HF6), SINAMICS S150 V5.1 (Control Unit) (All versions), SINAMICS S150 V5.1 SP1 (Control Unit) (All versions < V5.1 SP1 HF4), SINAMICS S210 V5.1 (Control Unit) (All versions), SINAMICS S210 V5.1 SP1 (Control Unit) (All versions), SITOP Manager (All versions), SITOP PSU8600 (All versions), SITOP UPS1600 (All versions), TIM 1531 IRC (All versions). The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
2035 CVE-2019-6561 352 CSRF 2019-03-05 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
Cross-site request forgery has been identified in Moxa IKS and EDS, which may allow for the execution of unauthorized actions on the device.
2036 CVE-2019-6556 416 Exec Code 2019-04-10 2019-04-15
6.8
None Remote Medium Not required Partial Partial Partial
When processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
2037 CVE-2019-6555 20 Exec Code 2019-02-28 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
Cscape, 9.80 SP4 and prior. An improper input validation vulnerability may be exploited by processing specially crafted POC files. This may allow an attacker to read confidential information and remotely execute arbitrary code.
2038 CVE-2019-6554 284 2019-04-05 2019-10-09
5.0
None Remote Low Not required None None Partial
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.
2039 CVE-2019-6548 798 2019-05-09 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
2040 CVE-2019-6546 427 2019-05-09 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
GE Communicator, all versions prior to 4.0.517, allows an attacker to place malicious files within the working directory of the program, which may allow an attacker to manipulate widgets and UI elements.
2041 CVE-2019-6544 284 2019-05-09 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
2042 CVE-2019-6541 119 Exec Code Overflow Mem. Corr. 2019-02-12 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
A memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
2043 CVE-2019-6537 119 Exec Code Overflow 2019-02-12 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage these vulnerabilities to execute code under the context of the current process. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
2044 CVE-2019-6536 787 Exec Code 2019-03-27 2019-04-02
6.8
None Remote Medium Not required Partial Partial Partial
Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.
2045 CVE-2019-6535 400 2019-02-05 2019-10-09
5.0
None Remote Low Not required None None Partial
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash.
2046 CVE-2019-6534 427 2019-04-11 2019-10-09
6.8
None Remote Medium Not required Partial Partial Partial
The uncontrolled search path element vulnerability in Gemalto Sentinel UltraPro Client Library ux32w.dll Versions 1.3.0, 1.3.1, and 1.3.2 enables an attacker to load and execute a malicious file.
2047 CVE-2019-6533 306 2019-02-12 2019-10-09
6.4
None Remote Low Not required Partial Partial None
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
2048 CVE-2019-6532 704 Exec Code 2019-06-07 2019-06-13
6.8
None Remote Medium Not required Partial Partial Partial
Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user triggering incompatible type errors because the resource does not have expected properties. This may lead to remote code execution.
2049 CVE-2019-6530 119 Exec Code Overflow 2019-06-07 2019-06-13
6.8
None Remote Medium Not required Partial Partial Partial
Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user causing heap-based buffer overflows, which may lead to remote code execution.
2050 CVE-2019-6528 20 Exec Code 2019-03-05 2019-10-09
6.5
None Remote Low Single system Partial Partial Partial
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
Total number of vulnerabilities : 40048   Page : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 (This Page)42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.