# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
1751 CVE-2017-6037 119 Overflow 2017-04-26 2017-05-05
9.3
None Remote Medium Not required Complete Complete Complete
A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system.
1752 CVE-2017-6035 119 DoS Overflow 2017-04-26 2017-05-05
9.3
None Remote Medium Not required Complete Complete Complete
A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system.
1753 CVE-2017-6023 119 Exec Code Overflow 2017-03-16 2017-03-31
9.0
None Remote Low Not required Partial Partial Complete
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.
1754 CVE-2017-5996 426 2017-10-26 2017-11-16
9.3
None Remote Medium Not required Complete Complete Complete
The agent in Bomgar Remote Support 15.2.x before 15.2.3, 16.1.x before 16.1.5, and 16.2.x before 16.2.4 allows DLL hijacking because of weak %SYSTEMDRIVE%\ProgramData permissions.
1755 CVE-2017-5859 320 2017-03-10 2017-03-13
10.0
None Remote Low Not required Complete Complete Complete
On Cambium Networks cnPilot R200/201 devices before 4.3, there is a vulnerability involving the certificate of the device and its RSA keys, aka RBN-183.
1756 CVE-2017-5824 Exec Code 2018-02-15 2018-03-07
10.0
None Remote Low Not required Complete Complete Complete
An unauthenticated remote code execution vulnerability in HPE Aruba ClearPass Policy Manager version 6.6.x was found.
1757 CVE-2017-5823 77 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1758 CVE-2017-5821 77 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1759 CVE-2017-5820 77 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1760 CVE-2017-5819 20 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1761 CVE-2017-5817 20 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1762 CVE-2017-5816 20 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1763 CVE-2017-5815 20 Exec Code 2018-02-15 2018-02-24
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 was found.
1764 CVE-2017-5814 89 Sql Bypass 2018-02-15 2018-03-07
10.0
None Remote Low Not required Complete Complete Complete
A remote sql injection authentication bypass in HPE Network Automation version 9.1x, 9.2x, 10.0x, 10.1x and 10.2x were found.
1765 CVE-2017-5807 119 Exec Code Overflow 2018-02-15 2018-03-07
10.0
None Remote Low Not required Complete Complete Complete
A Remote Arbitrary Code Execution vulnerability in HPE Data Protector version prior to 8.17 and 9.09 was found.
1766 CVE-2017-5806 20 Exec Code 2018-02-15 2018-03-06
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.2 was found.
1767 CVE-2017-5805 20 Exec Code 2018-02-15 2018-03-06
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.2 was found.
1768 CVE-2017-5804 190 Exec Code 2018-02-15 2018-03-06
10.0
None Remote Low Not required Complete Complete Complete
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.2 was found.
1769 CVE-2017-5802 264 +Priv 2018-02-15 2018-03-15
10.0
None Remote Low Not required Complete Complete Complete
A Remote Gain Privileged Access vulnerability in HPE Vertica Analytics Platform version v4.1 and later was found.
1770 CVE-2017-5796 352 CSRF 2018-02-15 2018-03-12
9.3
None Remote Medium Not required Complete Complete Complete
A Remote Cross Site Request Forgery (CSRF) vulnerability in HPE 2620 Series Network Switches version RA.15.05.0006 was found.
1771 CVE-2017-5794 20 2018-02-15 2018-03-07
9.0
None Remote Low Single system Complete Complete Complete
A Remote Arbitrary File Download vulnerability in HPE Intelligent Management Center (IMC) PLAT version 7.2 E0403P06 was found.
1772 CVE-2017-5793 20 Exec Code 2018-02-15 2018-03-07
9.0
None Remote Low Single system Complete Complete Complete
A Remote Arbitrary Code Execution vulnerability in HPE Intelligent Management Center (IMC) PLAT version 7.2 E0403P06 was found.
1773 CVE-2017-5791 287 Bypass 2017-10-11 2018-02-16
10.0
None Remote Low Not required Complete Complete Complete
The doFilter method in UrlAccessController in HPE Intelligent Management Center (iMC) PLAT 7.2 E0403P06 allows remote bypass of authentication via unspecified strings in a URI.
1774 CVE-2017-5790 502 2018-02-15 2018-03-07
10.0
None Remote Low Not required Complete Complete Complete
A remote deserialization of untrusted data vulnerability in HPE Intelligent Management Center (IMC) PLAT version 7.2 E0403P06 was found.
1775 CVE-2017-5712 119 Exec Code Overflow 2017-11-21 2018-05-10
9.0
None Remote Low Single system Complete Complete Complete
Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege.
1776 CVE-2017-5691 264 2017-07-26 2017-09-15
9.3
None Remote Medium Not required Complete Complete Complete
Incorrect check in Intel processors from 6th and 7th Generation Intel Core Processor Families, Intel Xeon E3-1500M v5 and v6 Product Families, and Intel Xeon E3-1200 v5 and v6 Product Families allows compromised system firmware to impact SGX security via incorrect early system state.
1777 CVE-2017-5689 264 +Priv 2017-05-02 2017-11-09
10.0
None Remote Low Not required Complete Complete Complete
An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).
1778 CVE-2017-5682 264 2017-02-28 2017-03-16
9.3
None Remote Medium Not required Complete Complete Complete
Intel PSET Application Install wrapper of Intel Parallel Studio XE, Intel System Studio, Intel VTune Amplifier, Intel Inspector, Intel Advisor, Intel MPI Library, Intel Trace Analyzer and Collector, Intel Integrated Performance Primitives, Cryptography for Intel Integrated Performance Primitives, Intel Math Kernel Library, Intel Data Analytics Acceleration Library, and Intel Threading Building Blocks before 2017 Update 2 allows an attacker to launch a process with escalated privileges.
1779 CVE-2017-5675 77 Exec Code 2017-03-13 2017-03-15
9.0
None Remote Low Single system Complete Complete Complete
A command-injection vulnerability exists in a web application on a custom-built GoAhead web server used on Foscam, Vstarcam, and multiple white-label IP camera models. The mail-sending form in the mail.htm page allows an attacker to inject a command into the receiver1 field in the form; it will be executed with root privileges.
1780 CVE-2017-5638 20 Exec Code 2017-03-10 2018-03-03
10.0
None Remote Low Not required Complete Complete Complete
The Jakarta Multipart parser in Apache Struts 2 2.3.x before 2.3.32 and 2.5.x before 2.5.10.1 has incorrect exception handling and error-message generation during file-upload attempts, which allows remote attackers to execute arbitrary commands via a crafted Content-Type, Content-Disposition, or Content-Length HTTP header, as exploited in the wild in March 2017 with a Content-Type header containing a #cmd= string.
1781 CVE-2017-5626 264 Exec Code 2017-03-12 2017-03-14
10.0
Admin Remote Low Not required Complete Complete Complete
OxygenOS before version 4.0.2, on OnePlus 3 and 3T, has two hidden fastboot oem commands (4F500301 and 4F500302) that allow the attacker to lock/unlock the bootloader, disregarding the 'OEM Unlocking' checkbox, without user confirmation and without a factory reset. This allows for persistent code execution with high privileges (kernel/root) with complete access to user data.
1782 CVE-2017-5624 264 Exec Code 2017-03-12 2017-03-14
10.0
None Remote Low Not required Complete Complete Complete
An issue was discovered in OxygenOS before 4.0.3 for OnePlus 3 and 3T. The attacker can persistently make the (locked) bootloader start the platform with dm-verity disabled, by issuing the 'fastboot oem disable_dm_verity' command. Having dm-verity disabled, the kernel will not verify the system partition (and any other dm-verity protected partition), which may allow for persistent code execution and privilege escalation.
1783 CVE-2017-5554 264 2017-01-23 2017-01-26
9.3
None Remote Medium Not required Complete Complete Complete
An issue was discovered in ABOOT in OnePlus 3 and 3T OxygenOS before 4.0.2. The attacker can reboot the device into the fastboot mode, which could be done without any authentication. A physical attacker can press the "Volume Up" button during device boot, where an attacker with ADB access can issue the adb reboot bootloader command. Then, the attacker can put the platform's SELinux in permissive mode, which severely weakens it, by issuing: fastboot oem selinux permissive.
1784 CVE-2017-5539 284 Dir. Trav. Bypass 2017-01-23 2017-01-26
9.0
None Remote Low Not required Complete Partial Partial
The patch for directory traversal (CVE-2017-5480) in b2evolution version 6.8.4-stable has a bypass vulnerability. An attacker can use ..\/ to bypass the filter rule. Then, this attacker can exploit this vulnerability to delete or read any files on the server. It can also be used to determine whether a file exists.
1785 CVE-2017-5538 125 2017-03-23 2017-03-28
10.0
None Remote Low Not required Complete Complete Complete
The kbase_dispatch function in arm/t7xx/r5p0/mali_kbase_core_linux.c in the GPU driver on Samsung devices with M(6.0) and N(7.0) software and Exynos AP chipsets allows attackers to have unspecified impact via unknown vectors, which trigger an out-of-bounds read, aka SVE-2016-6362.
1786 CVE-2017-5534 264 2017-12-12 2017-12-29
9.0
None Remote Low Single system Complete Complete Complete
The tibbr user profiles components of tibbr Community, and tibbr Enterprise expose a weakness in an improperly sandboxed third-party component. Affected releases are TIBCO Software Inc. tibbr Community 5.2.1 and below; 6.0.0; 6.0.1; 7.0.0, tibbr Enterprise 5.2.1 and below; 6.0.0; 6.0.1; 7.0.0.
1787 CVE-2017-5399 119 Overflow Mem. Corr. 2018-06-11 2018-08-01
10.0
None Remote Low Not required Complete Complete Complete
Memory safety bugs were reported in Firefox 51. Some of these bugs showed evidence of memory corruption and we presume that with enough effort that some of these could be exploited to run arbitrary code. This vulnerability affects Firefox < 52 and Thunderbird < 52.
1788 CVE-2017-5398 119 Overflow Mem. Corr. 2018-06-11 2018-08-01
10.0
None Remote Low Not required Complete Complete Complete
Memory safety bugs were reported in Thunderbird 45.7. Some of these bugs showed evidence of memory corruption and we presume that with enough effort that some of these could be exploited to run arbitrary code. This vulnerability affects Firefox < 52, Firefox ESR < 45.8, Thunderbird < 52, and Thunderbird < 45.8.
1789 CVE-2017-5397 264 2018-06-11 2018-08-07
10.0
None Remote Low Not required Complete Complete Complete
The cache directory on the local file system is set to be world writable. Firefox defaults to extracting libraries from this cache. This allows for the possibility of an installed malicious application or tools with write access to the file system to replace files used by Firefox with their own versions. This vulnerability affects Firefox < 51.0.3.
1790 CVE-2017-5260 16 2017-12-20 2018-01-10
9.0
None Remote Low Single system Complete Complete Complete
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, although the option to access the configuration file is not available in the normal web administrative console for the 'user' account, the configuration file is accessible via direct object reference (DRO) at http://<device-ip-or-hostname>/goform/down_cfg_file by this otherwise low privilege 'user' account.
1791 CVE-2017-5259 254 2017-12-20 2018-01-10
9.0
None Remote Low Single system Complete Complete Complete
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://<device-ip-or-hostname>/adm/syscmd.asp.
1792 CVE-2017-5255 77 2017-12-20 2018-01-10
9.0
None Remote Low Single system Complete Complete Complete
In version 3.5 and prior of Cambium Networks ePMP firmware, a lack of input sanitation for certain parameters on the web management console allows any authenticated user (including the otherwise low-privilege readonly user) to inject shell meta-characters as part of a specially-crafted POST request to the get_chart function and run OS-level commands, effectively as root.
1793 CVE-2017-5254 264 2017-12-20 2018-01-10
9.0
None Remote Low Single system Complete Complete Complete
In version 3.5 and prior of Cambium Networks ePMP firmware, the non-administrative users 'installer' and 'home' have the capability of changing passwords for other accounts, including admin, after disabling a client-side protection mechanism.
1794 CVE-2017-5219 254 2017-02-02 2017-03-14
10.0
None Remote Low Not required Complete Complete Complete
An issue was discovered in SageCRM 7.x before 7.3 SP3. The Component Manager functionality, provided by SageCRM, permits additional components to be added to the application to enhance provided functionality. This functionality allows a zip file to be uploaded, containing a valid .ecf component file, which will be extracted to the inf directory outside of the webroot. By creating a zip file containing an empty .ecf file, to pass file-validation checks, any other file provided in zip file will be extracted onto the filesystem. In this case, a web shell with the filename '..\WWWRoot\CustomPages\aspshell.asp' was included within the zip file that, when extracted, traversed back out of the inf directory and into the SageCRM webroot. This permitted remote interaction with the underlying filesystem with the highest privilege level, SYSTEM.
1795 CVE-2017-5200 77 Exec Code 2017-09-26 2017-10-06
9.0
None Remote Low Single system Complete Complete Complete
Salt-api in SaltStack Salt before 2015.8.13, 2016.3.x before 2016.3.5, and 2016.11.x before 2016.11.2 allows arbitrary command execution on a salt-master via Salt's ssh_client.
1796 CVE-2017-5178 255 2017-03-08 2017-03-16
10.0
None Remote Low Not required Complete Complete Complete
An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access.
1797 CVE-2017-5173 943 Exec Code 2017-05-18 2017-08-31
10.0
None Remote Low Not required Complete Complete Complete
An Improper Neutralization of Special Elements (in an OS command) issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An improper neutralization of special elements vulnerability has been identified. If special elements are not properly neutralized, an attacker can call multiple parameters that can allow access to the root level operating system which could allow remote code execution.
1798 CVE-2017-5162 306 2017-02-13 2017-02-16
10.0
None Remote Low Not required Complete Complete Complete
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
1799 CVE-2017-5161 427 2017-02-13 2017-03-15
9.3
None Remote Medium Not required Complete Complete Complete
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL.
1800 CVE-2017-5055 125 2017-10-27 2018-01-04
9.3
None Remote Medium Not required Complete Complete Complete
A use after free in printing in Google Chrome prior to 57.0.2987.133 for Linux and Windows allowed a remote attacker to perform an out of bounds memory read via a crafted HTML page.
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.