1101 CVE-2019-10992 125 2019-07-24 2019-07-29
4.3
None Remote Medium Not required Partial None None
Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple out-of-bounds read vulnerabilities may cause information disclosure due to lacking user input validation for processing project files.
1102 CVE-2019-10983 125 2019-06-28 2019-07-02
5.0
None Remote Low Not required Partial None None
In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information.
1103 CVE-2019-10981 255 2019-05-31 2019-06-03
2.1
None Local Low Not required Partial None None
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
1104 CVE-2019-10976 611 2019-07-25 2019-08-06
4.3
None Remote Medium Not required Partial None None
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.
1105 CVE-2019-10975 125 2019-07-02 2019-07-05
3.3
None Local Medium Not required Partial None Partial
An out-of-bounds read vulnerability has been identified in Fuji Electric Alpha7 PC Loader Versions 1.1 and prior, which may crash the system.
1106 CVE-2019-10974 119 Overflow 2019-07-25 2019-08-01
3.6
None Local Low Not required None Partial Partial
NREL EnergyPlus, Versions 8.6.0 and possibly prior versions, The application fails to prevent an exception handler from being overwritten with arbitrary code.
1107 CVE-2019-10968 284 2019-07-24 2019-08-01
2.1
None Local Low Not required None Partial None
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
1108 CVE-2019-10966 287 2019-07-10 2019-07-18
5.0
None Remote Low Not required None Partial None
In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.
1109 CVE-2019-10964 284 2019-06-28 2019-07-08
5.8
None Local Network Low Not required Partial Partial Partial
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump ? All versions, MiniMed Paradigm 511 pump ? All versions, MiniMed Paradigm 512/712 pumps ? All versions, MiniMed Paradigm 712E pump?All versions, MiniMed Paradigm 515/715 pumps?All versions, MiniMed Paradigm 522/722 pumps ? All versions,MiniMed Paradigm 522K/722K pumps ? All versions, MiniMed Paradigm 523/723 pumps ? Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps ? Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps ? Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only ? Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
1110 CVE-2019-10962 284 2019-06-13 2019-06-19
5.0
None Remote Low Not required Partial None None
BD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation terminal to gain access to the status and configuration information of the device.
1111 CVE-2019-10955 601 2019-04-25 2019-05-02
5.8
None Remote Medium Not required Partial Partial None
In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user?s machine.
1112 CVE-2019-10953 400 2019-04-17 2019-05-22
5.0
None Remote Low Not required None None Partial
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
1113 CVE-2019-10949 125 2019-04-17 2019-04-18
4.3
None Remote Medium Not required Partial None None
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple out-of-bounds read vulnerabilities may be exploited, allowing information disclosure due to a lack of user input validation for processing specially crafted project files.
1114 CVE-2019-10946 284 2019-04-10 2019-04-11
5.0
None Remote Low Not required None Partial None
An issue was discovered in Joomla! before 3.9.5. The "refresh list of helpsites" endpoint of com_users lacks access checks, allowing calls from unauthenticated users.
1115 CVE-2019-10943 2019-08-13 2019-08-13
0.0
None ??? ??? ??? ??? ??? ???
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7-1200 CPU family (All versions >= V4.0), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-PLCSIM Advanced (All versions). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device. No public exploitation of the vulnerability was known at the time of advisory publication.
1116 CVE-2019-10942 2019-08-13 2019-08-13
0.0
None ??? ??? ??? ??? ??? ???
A vulnerability has been identified in SCALANCE X-200 (All versions), SCALANCE X-200IRT (All versions), SCALANCE X-200RNA (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
1117 CVE-2019-10933 79 XSS 2019-07-11 2019-08-13
4.3
None Remote Medium Not required None Partial None
A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known.
1118 CVE-2019-10931 20 DoS 2019-07-11 2019-07-19
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions), DIGSI 5 engineering software (All versions < V7.90). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
1119 CVE-2019-10929 2019-08-13 2019-08-13
0.0
None ??? ??? ??? ??? ??? ???
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7-1200 CPU family (All versions >= V4.0), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-PLCSIM Advanced (All versions). An attacker in a Man-in-the-Middle position could potentially modify network traffic exchanged on port 102/tcp, due to certain properties in the calculation used for integrity protection. In order to exploit the vulnerability, an attacker must be able to perform a Man-in-the-Middle attack. The vulnerability could impact the integrity of the communication. No public exploitation of the vulnerability was known at the time of advisory publication.
1120 CVE-2019-10928 Exec Code 2019-08-13 2019-08-13
0.0
None ??? ??? ??? ??? ??? ???
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
1121 CVE-2019-10927 2019-08-13 2019-08-13
0.0
None ??? ??? ??? ??? ??? ???
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device.
1122 CVE-2019-10926 310 2019-06-12 2019-06-19
2.6
None Remote High Not required Partial None None
A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an attacker in a privileged network position which allows evesdropping the communication between the affected device and the user. The user must invoke a session. Successful exploitation of the vulnerability compromises confidentiality of the data transmitted. At the time of advisory publication no public exploitation of this security vulnerability was known.
1123 CVE-2019-10925 264 2019-06-12 2019-06-19
5.5
None Remote Low Single system None Partial Partial
A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
1124 CVE-2019-10921 255 2019-05-14 2019-05-30
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in LOGO!8 BM (All versions). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known
1125 CVE-2019-10920 798 2019-05-14 2019-05-30
5.0
None Remote Low Not required Partial None None
A vulnerability has been identified in LOGO!8 BM (All versions). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
1126 CVE-2019-10917 20 2019-05-14 2019-08-13
2.1
None Local Low Not required None None Partial
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions), SIMATIC WinCC (TIA Portal) V15 (All versions), SIMATIC WinCC Runtime Professional (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
1127 CVE-2019-10915 264 Exec Code 2019-07-11 2019-07-30
4.6
None Local Low Not required Partial Partial Partial
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
1128 CVE-2019-10909 79 XSS 2019-05-16 2019-05-20
3.5
None Remote Medium Single system None Partial None
In Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, validation messages are not escaped, which can lead to XSS when user input is included. This is related to symfony/framework-bundle.
1129 CVE-2019-10907 255 2019-04-07 2019-04-09
5.0
None Remote Low Not required Partial None None
Airsonic 10.2.1 uses Spring's default remember-me mechanism based on MD5, with a fixed key of airsonic in GlobalSecurityConfig.java. An attacker able to capture cookies might be able to trivially bruteforce offline the passwords of associated users.
1130 CVE-2019-10906 264 2019-04-06 2019-06-06
5.0
None Remote Low Not required Partial None None
In Pallets Jinja before 2.10.1, str.format_map allows a sandbox escape.
1131 CVE-2019-10904 79 XSS 2019-04-06 2019-04-09
4.3
None Remote Medium Not required None Partial None
Roundup 1.6 allows XSS via the URI because frontends/roundup.cgi and roundup/cgi/wsgi_handler.py mishandle 404 errors.
1132 CVE-2019-10903 399 2019-04-09 2019-05-25
5.0
None Remote Low Not required None None Partial
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the DCERPC SPOOLSS dissector could crash. This was addressed in epan/dissectors/packet-dcerpc-spoolss.c by adding a boundary check.
1133 CVE-2019-10902 399 2019-04-09 2019-04-23
5.0
None Remote Low Not required None None Partial
In Wireshark 3.0.0, the TSDNS dissector could crash. This was addressed in epan/dissectors/packet-tsdns.c by splitting strings safely.
1134 CVE-2019-10901 476 2019-04-09 2019-05-25
5.0
None Remote Low Not required None None Partial
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the LDSS dissector could crash. This was addressed in epan/dissectors/packet-ldss.c by handling file digests properly.
1135 CVE-2019-10900 399 2019-04-09 2019-04-23
5.0
None Remote Low Not required None None Partial
In Wireshark 3.0.0, the Rbm dissector could go into an infinite loop. This was addressed in epan/dissectors/file-rbm.c by handling unknown object types safely.
1136 CVE-2019-10899 119 Overflow 2019-04-09 2019-05-25
5.0
None Remote Low Not required None None Partial
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the SRVLOC dissector could crash. This was addressed in epan/dissectors/packet-srvloc.c by preventing a heap-based buffer under-read.
1137 CVE-2019-10898 399 2019-04-09 2019-04-23
5.0
None Remote Low Not required None None Partial
In Wireshark 3.0.0, the GSUP dissector could go into an infinite loop. This was addressed in epan/dissectors/packet-gsm_gsup.c by rejecting an invalid Information Element length.
1138 CVE-2019-10897 399 2019-04-09 2019-04-23
5.0
None Remote Low Not required None None Partial
In Wireshark 3.0.0, the IEEE 802.11 dissector could go into an infinite loop. This was addressed in epan/dissectors/packet-ieee80211.c by detecting cases in which the bit offset does not advance.
1139 CVE-2019-10896 399 2019-04-09 2019-05-16
5.0
None Remote Low Not required None None Partial
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the DOF dissector could crash. This was addressed in epan/dissectors/packet-dof.c by properly handling generated IID and OID bytes.
1140 CVE-2019-10895 20 2019-04-09 2019-05-25
5.0
None Remote Low Not required None None Partial
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the NetScaler file parser could crash. This was addressed in wiretap/netscaler.c by improving data validation.
1141 CVE-2019-10894 399 2019-04-09 2019-05-25
5.0
None Remote Low Not required None None Partial
In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the GSS-API dissector could crash. This was addressed in epan/dissectors/packet-gssapi.c by ensuring that a valid dissector is called.
1142 CVE-2019-10893 79 XSS 2019-04-18 2019-05-02
3.5
None Remote Medium Single system None Partial None
CentOS-WebPanel.com (aka CWP) CentOS Web Panel 0.9.8.793 (Free/Open Source Version) and 0.9.8.753 (Pro) is vulnerable to Stored/Persistent XSS for Admin Email fields on the "CWP Settings > "Edit Settings" screen. By changing the email ID to any XSS Payload and clicking on Save Changes, the XSS Payload will execute.
1143 CVE-2019-10887 74 2019-04-05 2019-04-08
4.3
None Remote Medium Not required None Partial None
A reflected HTML injection vulnerability on Salicru SLC-20-cube3(5) devices running firmware version cs121-SNMP v4.54.82.130611 allows remote attackers to inject arbitrary HTML elements via a /DataLog.csv?log= or /AlarmLog.csv?log= or /waitlog.cgi?name= or /chart.shtml?data= or /createlog.cgi?name= request.
1144 CVE-2019-10886 200 +Info 2019-04-19 2019-05-13
4.3
None Remote Medium Not required Partial None None
An incorrect access control exists in the Sony Photo Sharing Plus application in the firmware before PKG6.5629 version (for the X7500D TV and other applicable TVs). This vulnerability allows an attacker to read arbitrary files without authentication over HTTP when Photo Sharing Plus application is running. This may allow an attacker to browse a particular directory (e.g. images) inside the private network.
1145 CVE-2019-10885 264 Bypass 2019-04-05 2019-04-08
4.6
None Local Low Not required Partial Partial Partial
An issue was discovered in Ivanti Workspace Control before 10.3.90.0. Local authenticated users with low privileges in a Workspace Control managed session can bypass Workspace Control security features configured for this session by resetting the session context.
1146 CVE-2019-10884 255 2019-04-05 2019-04-10
4.3
None Remote Medium Not required Partial None None
Uniqkey Password Manager 1.14 contains a vulnerability because it fails to recognize the difference between domains and sub-domains. The vulnerability means that passwords saved for example.com will be recommended for usersite.example.com. This could lead to successful phishing campaigns and create a sense of false security.
1147 CVE-2019-10876 254 2019-04-05 2019-05-10
4.0
None Remote Low Single system Partial None None
An issue was discovered in OpenStack Neutron 11.x before 11.0.7, 12.x before 12.0.6, and 13.x before 13.0.3. By creating two security groups with separate/overlapping port ranges, an authenticated user may prevent Neutron from being able to configure networks on any compute nodes where those security groups are present, because of an Open vSwitch (OVS) firewall KeyError. All Neutron deployments utilizing neutron-openvswitch-agent are affected.
1148 CVE-2019-10875 20 2019-04-05 2019-04-15
4.3
None Remote Medium Not required None Partial None
A URL spoofing vulnerability was found in all international versions of Xiaomi Mi browser 10.5.6-g (aka the MIUI native browser) and Mint Browser 1.5.3 due to the way they handle the "q" query parameter. The portion of an https URL before the ?q= substring is not shown to the user.
1149 CVE-2019-10873 476 2019-04-05 2019-06-18
4.3
None Remote Medium Not required None None Partial
An issue was discovered in Poppler 0.74.0. There is a NULL pointer dereference in the function SplashClip::clipAALine at splash/SplashClip.cc.
1150 CVE-2019-10871 125 2019-04-05 2019-06-18
4.3
None Remote Medium Not required None None Partial
An issue was discovered in Poppler 0.74.0. There is a heap-based buffer over-read in the function PSOutputDev::checkPageSlice at PSOutputDev.cc.
Total number of vulnerabilities : 59258   Page : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 (This Page)24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.