Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device.
Products affected by CVE-2023-7017
Please log in to view affected product information.
Exploit prediction scoring system (EPSS) score for CVE-2023-7017
0.04%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 7 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2023-7017
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
9.8
|
CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
3.9
|
5.9
|
134c704f-9b21-4f2e-91b3-4a467353bcc0 | 2024-08-28 |