Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.
Published 2024-05-03 03:15:11
Updated 2024-05-03 12:50:12
View at NVD,   CVE.org
Vulnerability category: Execute code

Products affected by CVE-2023-39461

Please log in to view affected product information.

Exploit prediction scoring system (EPSS) score for CVE-2023-39461

0.56%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 66 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2023-39461

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
4.4
MEDIUM CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:N
0.7
3.6
Zero Day Initiative 2024-05-03

CWE ids for CVE-2023-39461