Vulnerability Details : CVE-2023-28832
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Vulnerability category: Execute code
Products affected by CVE-2023-28832
- cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2023-28832
0.16%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 52 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2023-28832
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
7.2
|
HIGH | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
1.2
|
5.9
|
Siemens AG |
CWE ids for CVE-2023-28832
-
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.Assigned by: productcert@siemens.com (Primary)
References for CVE-2023-28832
-
https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf
Patch;Vendor Advisory
Jump to