A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.
Published 2023-01-10 12:15:24
Updated 2023-01-14 00:43:07
Source Siemens AG
View at NVD,   CVE.org
Vulnerability category: Execute code

Exploit prediction scoring system (EPSS) score for CVE-2022-45094

Probability of exploitation activity in the next 30 days: 0.17%

Percentile, the proportion of vulnerabilities that are scored at or less: ~ 54 % EPSS Score History EPSS FAQ

CVSS scores for CVE-2022-45094

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source
8.8
HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.8
5.9
NIST
8.4
HIGH CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
1.7
6.0
Siemens AG

CWE ids for CVE-2022-45094

References for CVE-2022-45094

Products affected by CVE-2022-45094

This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.
By using this web site you are agreeing to CVEdetails.com terms of use!