A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.
Published 2023-01-10 12:15:24
Updated 2023-01-14 00:43:07
Source Siemens AG
View at NVD,   CVE.org
Vulnerability category: Execute code

Products affected by CVE-2022-45094

Exploit prediction scoring system (EPSS) score for CVE-2022-45094

0.20%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 59 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-45094

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
8.8
HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.8
5.9
NIST
8.4
HIGH CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
1.7
6.0
Siemens AG

CWE ids for CVE-2022-45094