Vulnerability Details : CVE-2022-45093
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.
Vulnerability category: Directory traversalExecute code
Products affected by CVE-2022-45093
- cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*
- cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*
- cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*
- cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2022-45093
0.20%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 58 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2022-45093
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
8.8
|
HIGH | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
2.8
|
5.9
|
NIST | |
8.5
|
HIGH | CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H |
1.8
|
6.0
|
Siemens AG |
CWE ids for CVE-2022-45093
-
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.Assigned by: productcert@siemens.com (Primary)
References for CVE-2022-45093
-
https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf
Vendor Advisory
Jump to