Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal).
Published 2022-11-01 21:15:12
Updated 2023-03-31 16:12:15
Source SICK AG
View at NVD,   CVE.org

Products affected by CVE-2022-43990

Exploit prediction scoring system (EPSS) score for CVE-2022-43990

0.14%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 50 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-43990

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
7.3
HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
3.9
3.4
NIST

CWE ids for CVE-2022-43990

  • The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.