The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device's physical environment.
Published 2023-01-20 17:15:11
Updated 2023-01-27 15:05:28
Source MITRE
View at NVD,   CVE.org

Products affected by CVE-2022-43704

Exploit prediction scoring system (EPSS) score for CVE-2022-43704

0.06%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 29 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-43704

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
5.9
MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
2.2
3.6
NIST

CWE ids for CVE-2022-43704

  • A capture-replay flaw exists when the design of the product makes it possible for a malicious user to sniff network traffic and bypass authentication by replaying it to the server in question to the same effect as the original message (or with minor changes).