A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session.
Published 2022-11-08 11:15:12
Updated 2024-01-09 10:15:14
Source Siemens AG
View at NVD,   CVE.org

Products affected by CVE-2022-43398

Exploit prediction scoring system (EPSS) score for CVE-2022-43398

0.22%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 60 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-43398

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
8.8
HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
2.8
5.9
NIST
7.5
HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
1.6
5.9
Siemens AG

CWE ids for CVE-2022-43398

  • Authenticating a user, or otherwise establishing a new user session, without invalidating any existing session identifier gives an attacker the opportunity to steal authenticated sessions.
    Assigned by:
    • nvd@nist.gov (Primary)
    • productcert@siemens.com (Secondary)
Jump to
This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.