Vulnerability Details : CVE-2022-41772
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Vulnerability category: Directory traversalExecute code
Products affected by CVE-2022-41772
- cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2022-41772
0.41%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 74 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2022-41772
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
9.8
|
CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
3.9
|
5.9
|
ICS-CERT | |
9.8
|
CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
3.9
|
5.9
|
NIST |
CWE ids for CVE-2022-41772
-
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.Assigned by: ics-cert@hq.dhs.gov (Primary)
References for CVE-2022-41772
-
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07
Delta Electronics InfraSuite Device Master | CISAPatch;Third Party Advisory;US Government Resource