A vulnerability classified as critical was found in SourceCodester Cashier Queuing System 1.0. This vulnerability affects unknown code of the file /queuing/login.php of the component Login Page. The manipulation of the argument username/password leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-211186 is the identifier assigned to this vulnerability.
Published 2022-10-18 11:15:10
Updated 2024-01-25 21:15:53
Source VulDB
View at NVD,   CVE.org
Vulnerability category: Sql Injection

Exploit prediction scoring system (EPSS) score for CVE-2022-3579

0.17%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 54 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-3579

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
6.3
MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
2.8
3.4
VulDB
8.8
HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.8
5.9
NIST
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
NIST 2024-01-25

CWE ids for CVE-2022-3579

  • The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
    Assigned by: cna@vuldb.com (Primary)
  • The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data.
    Assigned by:
    • cna@vuldb.com (Primary)
    • nvd@nist.gov (Primary)
  • The product does not ensure or incorrectly ensures that structured messages or data are well-formed and that certain security properties are met before being read from an upstream component or sent to a downstream component.
    Assigned by: cna@vuldb.com (Secondary)

References for CVE-2022-3579

Products affected by CVE-2022-3579

This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.
By using this web site you are agreeing to CVEdetails.com terms of use!