Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to  1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
Published 2022-09-16 19:15:10
Updated 2024-01-25 21:17:10
Source ICS-CERT
View at NVD,   CVE.org
Vulnerability category: Execute code

Products affected by CVE-2022-3214

Exploit prediction scoring system (EPSS) score for CVE-2022-3214

2.20%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 84 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-3214

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
ICS-CERT
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
NIST

CWE ids for CVE-2022-3214

  • The product contains hard-coded credentials, such as a password or cryptographic key.
    Assigned by:
    • ics-cert@hq.dhs.gov (Primary)
    • nvd@nist.gov (Secondary)

References for CVE-2022-3214