A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy RTU500 series CMU Firmware 12.0.*; 12.2.*; 12.4.*; 12.6.*; 12.7.*; 13.2.*.
Published 2022-05-02 19:15:09
Updated 2023-07-21 16:43:00
View at NVD,   CVE.org
Vulnerability category: Input validation

Exploit prediction scoring system (EPSS) score for CVE-2022-28613

0.09%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 38 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-28613

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
7.8
HIGH AV:N/AC:L/Au:N/C:N/I:N/A:C
10.0
6.9
NIST
7.5
HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
3.9
3.6
Hitachi ABB Power Grids
7.5
HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
3.9
3.6
NIST

CWE ids for CVE-2022-28613

  • The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.
    Assigned by:
    • cybersecurity@hitachienergy.com (Secondary)
    • nvd@nist.gov (Primary)
  • The product receives input that is expected to specify a quantity (such as size or length), but it does not validate or incorrectly validates that the quantity has the required properties.
    Assigned by: nvd@nist.gov (Primary)

Products affected by CVE-2022-28613

This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.