A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
Published 2022-04-12 09:15:14
Updated 2022-04-19 16:01:50
Source Siemens AG
View at NVD,   CVE.org

Products affected by CVE-2022-23448

Exploit prediction scoring system (EPSS) score for CVE-2022-23448

0.04%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 11 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-23448

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
7.2
HIGH AV:L/AC:L/Au:N/C:C/I:C/A:C
3.9
10.0
NIST
7.8
HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
1.8
5.9
NIST

CWE ids for CVE-2022-23448

References for CVE-2022-23448