The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Published 2022-09-06 23:15:08
Updated 2022-09-12 13:53:58
Source ICS-CERT
View at NVD,   CVE.org

Products affected by CVE-2022-1368

Exploit prediction scoring system (EPSS) score for CVE-2022-1368

0.22%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 60 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2022-1368

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
ICS-CERT
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
NIST

CWE ids for CVE-2022-1368

References for CVE-2022-1368