Vulnerability Details : CVE-2021-38416
Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.
Products affected by CVE-2021-38416
- cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2021-38416
0.05%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 12 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2021-38416
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
4.4
|
MEDIUM | AV:L/AC:M/Au:N/C:P/I:P/A:P |
3.4
|
6.4
|
NIST | |
7.8
|
HIGH | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
1.8
|
5.9
|
ICS-CERT | |
7.8
|
HIGH | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
1.8
|
5.9
|
NIST |
CWE ids for CVE-2021-38416
-
The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.Assigned by: ics-cert@hq.dhs.gov (Primary)
References for CVE-2021-38416
-
https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02
Delta Electronics DIALink | CISAThird Party Advisory;US Government Resource