Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre.
Published 2022-03-23 20:15:09
Updated 2022-07-29 13:59:00
Source ICS-CERT
View at NVD,   CVE.org

Exploit prediction scoring system (EPSS) score for CVE-2021-27474

0.06%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 23 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2021-27474

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
5.0
MEDIUM AV:N/AC:L/Au:N/C:N/I:P/A:N
10.0
2.9
NIST
10.0
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:H
3.9
5.8
ICS-CERT
7.5
HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
3.9
3.6
NIST

CWE ids for CVE-2021-27474

  • The product invokes a potentially dangerous function that could introduce a vulnerability if it is used incorrectly, but the function can also be used safely.
    Assigned by: ics-cert@hq.dhs.gov (Secondary)

References for CVE-2021-27474

Products affected by CVE-2021-27474

This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.