An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
Products affected by CVE-2020-5807
- cpe:2.3:a:rockwellautomation:factorytalk_diagnostics:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2020-5807
0.08%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 36 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2020-5807
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
5.0
|
MEDIUM | AV:N/AC:L/Au:N/C:N/I:N/A:P |
10.0
|
2.9
|
NIST | |
7.5
|
HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
3.9
|
3.6
|
NIST |
CWE ids for CVE-2020-5807
-
The product does not handle or incorrectly handles an exceptional condition.Assigned by: nvd@nist.gov (Primary)
References for CVE-2020-5807
-
https://www.tenable.com/security/research/tra-2020-71
Rockwell Automation FactoryTalk Multiple Vulnerabilities - Research Advisory | TenableĀ®Third Party Advisory