Vulnerability Details : CVE-2020-25176
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.
Vulnerability category: Directory traversalExecute code
Products affected by CVE-2020-25176
- cpe:2.3:o:rockwellautomation:micro810_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:rockwellautomation:micro820_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:rockwellautomation:micro830_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:rockwellautomation:micro850_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:rockwellautomation:micro870_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:a:rockwellautomation:aadvance_controller:*:*:*:*:*:*:*:*
- Rockwellautomation » Isagraf Free Runtime » For Isagraf6 WorkbenchVersions up to, including, (<=) 6.6.8cpe:2.3:a:rockwellautomation:isagraf_free_runtime:*:*:*:*:*:isagraf6_workbench:*:*
- cpe:2.3:a:rockwellautomation:isagraf_runtime:*:*:*:*:*:*:*:*
- cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:schneider-electric:easergy_c5_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:schneider-electric:micom_c264_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.1:*:*:*:*:windows:*:*
- cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.2:*:*:*:*:windows:*:*
- cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.1:*:*:*:*:windows:*:*
- cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:linux:*:*
- cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:windows:*:*
- cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:linux:*:*
- cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:windows:*:*
- cpe:2.3:o:schneider-electric:saitel_dr_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:schneider-electric:scd2200_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:xylem:multismart_firmware:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2020-25176
3.95%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 87 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2020-25176
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
9.3
|
HIGH | AV:N/AC:M/Au:N/C:C/I:C/A:C |
8.6
|
10.0
|
NIST | |
9.1
|
CRITICAL | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
2.3
|
6.0
|
ICS-CERT | |
9.8
|
CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
3.9
|
5.9
|
NIST |
CWE ids for CVE-2020-25176
-
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.Assigned by: nvd@nist.gov (Primary)
-
The product uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize sequences such as ".." that can resolve to a location that is outside of that directory.Assigned by: ics-cert@hq.dhs.gov (Secondary)
References for CVE-2020-25176
-
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04
Mitigation;Vendor Advisory
-
https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01
Rockwell Automation ISaGRAF5 Runtime (Update A) | CISAThird Party Advisory;US Government Resource
-
https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-rockwell-isagraf.pdf
Third Party Advisory
-
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699
Rockwell Automation - Sign InPermissions Required