A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
Published 2020-09-09 19:15:20
Updated 2021-06-08 20:15:08
Source Siemens AG
View at NVD,   CVE.org
Vulnerability category: BypassGain privilege

Exploit prediction scoring system (EPSS) score for CVE-2020-15787

1.19%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 85 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2020-15787

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
5.0
MEDIUM AV:N/AC:L/Au:N/C:P/I:N/A:N
10.0
2.9
NIST
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
NIST

CWE ids for CVE-2020-15787

  • When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
    Assigned by: nvd@nist.gov (Secondary)
  • The authentication algorithm is sound, but the implemented mechanism can be bypassed as the result of a separate weakness that is primary to the authentication error.