A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.
Vulnerability category: Cross site scripting (XSS)
Products affected by CVE-2020-15781
- cpe:2.3:o:siemens:sicam_a8000_firmware:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2020-15781
0.15%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 50 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2020-15781
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
6.8
|
MEDIUM | AV:N/AC:M/Au:N/C:P/I:P/A:P |
8.6
|
6.4
|
NIST | |
9.6
|
CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H |
2.8
|
6.0
|
NIST |
CWE ids for CVE-2020-15781
-
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.Assigned by:
- nvd@nist.gov (Primary)
- productcert@siemens.com (Secondary)
References for CVE-2020-15781
-
https://cert-portal.siemens.com/productcert/pdf/ssa-370042.pdf