Vulnerability Details : CVE-2020-10051
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.
Products affected by CVE-2020-10051
- cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2020-10051
0.04%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 9 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2020-10051
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
7.2
|
HIGH | AV:L/AC:L/Au:N/C:C/I:C/A:C |
3.9
|
10.0
|
NIST | |
7.8
|
HIGH | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
1.8
|
5.9
|
NIST |
CWE ids for CVE-2020-10051
-
The product uses a search path that contains an unquoted element, in which the element contains whitespace or other separators. This can cause the product to access resources in a parent path.Assigned by:
- nvd@nist.gov (Primary)
- productcert@siemens.com (Secondary)
References for CVE-2020-10051
-
https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf
Vendor Advisory
Jump to