Vulnerability Details : CVE-2019-10964

In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump ? All versions, MiniMed Paradigm 511 pump ? All versions, MiniMed Paradigm 512/712 pumps ? All versions, MiniMed Paradigm 712E pump?All versions, MiniMed Paradigm 515/715 pumps?All versions, MiniMed Paradigm 522/722 pumps ? All versions,MiniMed Paradigm 522K/722K pumps ? All versions, MiniMed Paradigm 523/723 pumps ? Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps ? Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps ? Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only ? Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
Publish Date : 2019-06-28 Last Update Date : 2019-07-08
Search Twitter   Search YouTube   Search Google

- CVSS Scores & Vulnerability Types

CVSS Score
5.8
Confidentiality Impact Partial (There is considerable informational disclosure.)
Integrity Impact Partial (Modification of some system files or information is possible, but the attacker does not have control over what can be modified, or the scope of what the attacker can affect is limited.)
Availability Impact Partial (There is reduced performance or interruptions in resource availability.)
Access Complexity Low (Specialized access conditions or extenuating circumstances do not exist. Very little knowledge or skill is required to exploit. )
Authentication Not required (Authentication is not required to exploit the vulnerability.)
Gained Access None
Vulnerability Type(s)
CWE ID 284

- Products Affected By CVE-2019-10964

# Product Type Vendor Product Version Update Edition Language
1 OS Medtronic Minimed 508 Firmware Version Details Vulnerabilities
2 OS Medtronic Minimed Paradigm 511 Firmware Version Details Vulnerabilities
3 OS Medtronic Minimed Paradigm 512 Firmware Version Details Vulnerabilities
4 OS Medtronic Minimed Paradigm 515 Firmware Version Details Vulnerabilities
5 OS Medtronic Minimed Paradigm 522 Firmware Version Details Vulnerabilities
6 OS Medtronic Minimed Paradigm 522k Firmware Version Details Vulnerabilities
7 OS Medtronic Minimed Paradigm 523 Firmware 2.4a Version Details Vulnerabilities
8 OS Medtronic Minimed Paradigm 523k Firmware 2.4a Version Details Vulnerabilities
9 OS Medtronic Minimed Paradigm 712 Firmware Version Details Vulnerabilities
10 OS Medtronic Minimed Paradigm 712e Firmware Version Details Vulnerabilities
11 OS Medtronic Minimed Paradigm 715 Firmware Version Details Vulnerabilities
12 OS Medtronic Minimed Paradigm 722 Firmware Version Details Vulnerabilities
13 OS Medtronic Minimed Paradigm 722k Firmware Version Details Vulnerabilities
14 OS Medtronic Minimed Paradigm 723 Firmware 2.4a Version Details Vulnerabilities
15 OS Medtronic Minimed Paradigm 723k Firmware 2.4a Version Details Vulnerabilities
16 OS Medtronic Minimed Paradigm Veo 554 Firmware 2.6a Version Details Vulnerabilities
17 OS Medtronic Minimed Paradigm Veo 554cm Firmware 2.7a Version Details Vulnerabilities
18 OS Medtronic Minimed Paradigm Veo 754 Firmware 2.6a Version Details Vulnerabilities
19 OS Medtronic Minimed Paradigm Veo 754cm Firmware - Version Details Vulnerabilities

- Number Of Affected Versions By Product

Vendor Product Vulnerable Versions
Medtronic Minimed 508 Firmware 1
Medtronic Minimed Paradigm 511 Firmware 1
Medtronic Minimed Paradigm 512 Firmware 1
Medtronic Minimed Paradigm 515 Firmware 1
Medtronic Minimed Paradigm 522 Firmware 1
Medtronic Minimed Paradigm 522k Firmware 1
Medtronic Minimed Paradigm 523 Firmware 1
Medtronic Minimed Paradigm 523k Firmware 1
Medtronic Minimed Paradigm 712 Firmware 1
Medtronic Minimed Paradigm 712e Firmware 1
Medtronic Minimed Paradigm 715 Firmware 1
Medtronic Minimed Paradigm 722 Firmware 1
Medtronic Minimed Paradigm 722k Firmware 1
Medtronic Minimed Paradigm 723 Firmware 1
Medtronic Minimed Paradigm 723k Firmware 1
Medtronic Minimed Paradigm Veo 554 Firmware 1
Medtronic Minimed Paradigm Veo 554cm Firmware 1
Medtronic Minimed Paradigm Veo 754 Firmware 1
Medtronic Minimed Paradigm Veo 754cm Firmware 1

- References For CVE-2019-10964

http://www.securityfocus.com/bid/108926
BID 108926 Multiple Medtronic Products CVE-2019-10964 Security Bypass Vulnerability Release Date:2019-06-27
https://www.us-cert.gov/ics/advisories/icsma-19-178-01

- Vulnerability Conditions

Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)
Vulnerability is valid if product versions listed below are used TOGETHER WITH(AND)

- Metasploit Modules Related To CVE-2019-10964

There are not any metasploit modules related to this CVE entry (Please visit www.metasploit.com for more information)


CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.