A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published 2020-01-16 16:15:16
Updated 2021-09-20 12:15:10
Source Siemens AG
View at NVD,   CVE.org

Products affected by CVE-2019-10940

Exploit prediction scoring system (EPSS) score for CVE-2019-10940

0.14%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 50 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2019-10940

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
9.0
HIGH AV:N/AC:L/Au:S/C:C/I:C/A:C
8.0
10.0
NIST
9.9
CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
3.1
6.0
NIST

CWE ids for CVE-2019-10940

  • A product incorrectly assigns a privilege to a particular actor, creating an unintended sphere of control for that actor.
    Assigned by: productcert@siemens.com (Secondary)
  • The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
    Assigned by: nvd@nist.gov (Primary)