A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Published 2018-06-14 16:29:00
Updated 2022-12-13 17:15:12
Source Siemens AG
View at NVD,   CVE.org
Vulnerability category: Cross site scripting (XSS)

Exploit prediction scoring system (EPSS) score for CVE-2018-4842

0.07%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 28 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2018-4842

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
3.5
LOW AV:N/AC:M/Au:S/C:N/I:P/A:N
6.8
2.9
NIST
4.8
MEDIUM CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
1.7
2.7
NIST

CWE ids for CVE-2018-4842

References for CVE-2018-4842

Products affected by CVE-2018-4842

This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.