An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.
Products affected by CVE-2018-17064
- cpe:2.3:o:dlink:dir-816_a2_firmware:1.10_b05:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2018-17064
1.35%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 84 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2018-17064
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
10.0
|
HIGH | AV:N/AC:L/Au:N/C:C/I:C/A:C |
10.0
|
10.0
|
NIST | |
9.8
|
CRITICAL | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
3.9
|
5.9
|
NIST |
CWE ids for CVE-2018-17064
-
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.Assigned by: nvd@nist.gov (Primary)