Vulnerability Details : CVE-2018-11457
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.
Vulnerability category: OverflowExecute code
Products affected by CVE-2018-11457
- cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2018-11457
0.63%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 79 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2018-11457
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
9.3
|
HIGH | AV:N/AC:M/Au:N/C:C/I:C/A:C |
8.6
|
10.0
|
NIST | |
8.1
|
HIGH | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
2.2
|
5.9
|
NIST |
CWE ids for CVE-2018-11457
-
A heap overflow condition is a buffer overflow, where the buffer that can be overwritten is allocated in the heap portion of memory, generally meaning that the buffer was allocated using a routine such as malloc().Assigned by: productcert@siemens.com (Secondary)
References for CVE-2018-11457
-
https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf
Vendor Advisory
-
http://www.securityfocus.com/bid/106185
Siemens SINUMERIK Controllers Multiple Security VulnerabilitiesThird Party Advisory;VDB Entry