Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
Published 2019-07-03 16:15:10
Updated 2020-08-24 17:37:01
Source MITRE
View at NVD,   CVE.org

Products affected by CVE-2018-11421

Exploit prediction scoring system (EPSS) score for CVE-2018-11421

0.19%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 57 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2018-11421

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
5.0
MEDIUM AV:N/AC:L/Au:N/C:P/I:N/A:N
10.0
2.9
NIST
9.8
CRITICAL CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
NIST

CWE ids for CVE-2018-11421

References for CVE-2018-11421

Jump to
This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.
By using this web site you are agreeing to CVEdetails.com terms of use!