Vulnerability Details : CVE-2017-9858
An issue was discovered in SMA Solar Technology products. By sending crafted packets to an inverter and observing the response, active and inactive user accounts can be determined. This aids in further attacks (such as a brute force attack) as one now knows exactly which users exist and which do not. NOTE: the vendor's position is that this "is not a security gap per se." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Products affected by CVE-2017-9858
- cpe:2.3:o:sma:sunny_boy_3600_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_5000_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_core1_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_15000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_20000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_25000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_5000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_12000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_tripower_60_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_3000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_3600tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_4000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_5000tl_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_1.5_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_2.5_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_3.0_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_3.6_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_4.0_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_5.0_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_2200_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_1000cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_800cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_850cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_900cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_500cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_630cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_720cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_760cp_xt_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_500_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_630_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_720_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_760_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_800_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_850_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_900_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_1000_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_2200_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_central_storage_2500-ev_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:sma:sunny_boy_storage_2.5_firmware:-:*:*:*:*:*:*:*
Exploit prediction scoring system (EPSS) score for CVE-2017-9858
0.18%
Probability of exploitation activity in the next 30 days
EPSS Score History
~ 55 %
Percentile, the proportion of vulnerabilities that are scored at or less
CVSS scores for CVE-2017-9858
Base Score | Base Severity | CVSS Vector | Exploitability Score | Impact Score | Score Source | First Seen |
---|---|---|---|---|---|---|
5.0
|
MEDIUM | AV:N/AC:L/Au:N/C:P/I:N/A:N |
10.0
|
2.9
|
NIST | |
7.5
|
HIGH | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
3.9
|
3.6
|
NIST |
CWE ids for CVE-2017-9858
-
The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information.Assigned by: nvd@nist.gov (Primary)
References for CVE-2017-9858
-
https://horusscenario.com/CVE-information/
CVE-Information – Horus ScenarioThird Party Advisory
-
http://www.sma.de/en/statement-on-cyber-security.html
Statement on Cyber Security
-
http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf