An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Published 2017-08-05 17:29:01
Updated 2024-08-05 18:15:30
Source MITRE
View at NVD,   CVE.org

Exploit prediction scoring system (EPSS) score for CVE-2017-9855

0.28%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 69 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2017-9855

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
7.5
HIGH AV:N/AC:L/Au:N/C:P/I:P/A:P
10.0
6.4
NIST
9.8
CRITICAL CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
NIST
9.8
CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.9
5.9
134c704f-9b21-4f2e-91b3-4a467353bcc0 2024-07-03

CWE ids for CVE-2017-9855

  • The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
    Assigned by: 134c704f-9b21-4f2e-91b3-4a467353bcc0 (Secondary)

Products affected by CVE-2017-9855

This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.
By using this web site you are agreeing to CVEdetails.com terms of use!