Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service (invalid 0x00 write operation and daemon crash) or possibly have unspecified other impact via a port-46824 TCP packet with a crafted negative integer after the opcode. NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-4358.
Published 2012-08-19 20:55:02
Updated 2012-08-20 04:00:00
Source MITRE
View at NVD,   CVE.org
Vulnerability category: Input validationDenial of service

Products affected by CVE-2012-4359

Exploit prediction scoring system (EPSS) score for CVE-2012-4359

0.94%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 83 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2012-4359

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
9.3
HIGH AV:N/AC:M/Au:N/C:C/I:C/A:C
8.6
10.0
NIST

CWE ids for CVE-2012-4359

  • The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.
    Assigned by: nvd@nist.gov (Primary)
Jump to
This web site uses cookies for managing your session, storing preferences, website analytics and additional purposes described in our privacy policy.
By using this web site you are agreeing to CVEdetails.com terms of use!