The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
Published 2012-02-03 20:55:01
Updated 2012-02-07 05:00:00
Source CERT/CC
View at NVD,   CVE.org
Vulnerability category: BypassGain privilege

Exploit prediction scoring system (EPSS) score for CVE-2011-4508

0.41%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 74 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2011-4508

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
9.3
HIGH AV:N/AC:M/Au:N/C:C/I:C/A:C
8.6
10.0
NIST

CWE ids for CVE-2011-4508

  • When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.