Stack-based buffer overflow in the SetActiveXGUID method in the VersionInfo ActiveX control in GenVersion.dll 8.0.138.0 in the WebHMI subsystem in ICONICS BizViz 9.x before 9.22 and GENESIS32 9.x before 9.22 allows remote attackers to execute arbitrary code via a long string in the argument. NOTE: some of these details are obtained from third party information.
Published 2011-05-13 17:05:46
Updated 2017-08-29 01:29:16
Source MITRE
View at NVD,   CVE.org
Vulnerability category: OverflowExecute code

Products affected by CVE-2011-2089

Exploit prediction scoring system (EPSS) score for CVE-2011-2089

50.75%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 97 %
Percentile, the proportion of vulnerabilities that are scored at or less

Metasploit modules for CVE-2011-2089

  • ICONICS WebHMI ActiveX Buffer Overflow
    Disclosure Date: 2011-05-05
    First seen: 2020-04-26
    exploit/windows/scada/iconics_webhmi_setactivexguid
    This module exploits a vulnerability found in ICONICS WebHMI's ActiveX control. By supplying a long string of data to the 'SetActiveXGUID' parameter, GenVersion.dll fails to do any proper bounds checking before this input is copied onto the stack, which causes a bu

CVSS scores for CVE-2011-2089

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
9.3
HIGH AV:N/AC:M/Au:N/C:C/I:C/A:C
8.6
10.0
NIST

CWE ids for CVE-2011-2089

  • The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.