Multiple stack-based buffer overflows in GE Intelligent Platforms Proficy Applications before 4.4.1 SIM 101 and 5.x before 5.0 SIM 43 allow remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic to (1) PRProficyMgr.exe in Proficy Server Manager, (2) PRGateway.exe in Proficy Server Gateway, (3) PRRDS.exe in Proficy Remote Data Service, or (4) PRLicenseMgr.exe in Proficy Server License Manager.
Published 2011-11-02 17:55:01
Updated 2011-11-17 05:00:00
Source CERT/CC
View at NVD,   CVE.org
Vulnerability category: OverflowExecute codeDenial of service

Products affected by CVE-2011-1919

Exploit prediction scoring system (EPSS) score for CVE-2011-1919

4.15%
Probability of exploitation activity in the next 30 days EPSS Score History
~ 92 %
Percentile, the proportion of vulnerabilities that are scored at or less

CVSS scores for CVE-2011-1919

Base Score Base Severity CVSS Vector Exploitability Score Impact Score Score Source First Seen
10.0
HIGH AV:N/AC:L/Au:N/C:C/I:C/A:C
10.0
10.0
NIST

CWE ids for CVE-2011-1919

  • The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.