APC : Security Vulnerabilities

Press ESC to close
# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
1 CVE-2011-4263 79 XSS 2011-12-07 2011-12-08
4.3
None Remote Medium Not required None Partial None
Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
2 CVE-2009-4406 79 XSS 2009-12-23 2009-12-28
4.3
None Remote Medium Not required None Partial None
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter.
3 CVE-2009-1798 79 XSS 2009-12-28 2010-06-29
4.3
None Remote Medium Not required None Partial None
Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. NOTE: the login_username vector for Forms/login1 is already covered by CVE-2009-4406.
4 CVE-2009-1797 352 CSRF 2009-12-28 2010-06-29
6.8
User Remote Medium Not required Partial Partial Partial
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to hijack the authentication of (1) administrator or (2) device users for requests that create new administrative users or have unspecified other impact.
5 CVE-2007-6226 287 Bypass 2007-12-04 2008-09-05
7.1
None Remote Medium Not required None None Complete
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits.
6 CVE-2005-4326 2005-12-17 2008-09-05
5.0
None Remote Low Not required Partial None None
The web interface for American Power Conversion (APC) PowerChute Network Shutdown performs all communication in cleartext (base64-encoded), which allows remote attackers to sniff authentication credentials.
7 CVE-2004-2046 DoS 2004-12-31 2008-09-10
5.0
None Remote Low Not required None None Partial
Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors.
8 CVE-2004-0311 2004-11-23 2008-09-05
10.0
Admin Remote Low Not required Complete Complete Complete
American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access.
9 CVE-2003-0099 DoS Exec Code Overflow 2003-03-03 2008-09-10
7.2
Admin Local Low Not required Complete Complete Complete
Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function.
10 CVE-2003-0098 +Priv 2003-03-03 2008-09-10
10.0
Admin Remote Low Not required Complete Complete Complete
Unknown vulnerability in apcupsd before 3.8.6, and 3.10.x before 3.10.5, allows remote attackers to gain root privileges, possibly via format strings in a request to a slave server.
11 CVE-2002-1924 2002-12-31 2008-09-05
5.0
None Remote Low Not required None Partial None
PowerChute plus 5.0.2 creates a "Pwrchute" directory during installation that is shared and world writeable, which could allow remote attackers to modify or create files in that directory.
12 CVE-2001-0564 DoS 2001-08-22 2008-09-10
5.0
None Remote Low Not required None None Partial
APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attempts which temporarily locks the card.
13 CVE-2001-0040 2001-02-16 2008-09-05
2.1
None Local Low Not required None None Partial
APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid file.
14 CVE-2000-1242 2000-12-31 2008-09-05
9.0
Admin Remote Low Single system Complete Complete Complete
The HTTP service in American Power Conversion (APC) PowerChute uses a default username and password, which allows remote attackers to gain system access.
Total number of vulnerabilities : 14   Page : 1 (This Page)
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.