# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
1 CVE-2014-0753 119 DoS Overflow 2014-01-20 2014-01-22
7.8
None Remote Low Not required None None Complete
Stack-based buffer overflow in the SCADA server in Ecava IntegraXor before 4.1.4390 allows remote attackers to cause a denial of service (system crash) by triggering access to DLL code located in the IntegraXor directory.
2 CVE-2014-0752 264 2014-01-09 2014-01-10
5.0
None Remote Low Not required Partial None None
The SCADA server in Ecava IntegraXor before 4.1.4369 allows remote attackers to read arbitrary project backup files via a crafted URL.
3 CVE-2012-0246 22 Exec Code Dir. Trav. 2012-04-02 2012-08-15
9.3
None Remote Medium Not required Complete Complete Complete
Directory traversal vulnerability in an unspecified ActiveX control in Ecava IntegraXor before 3.71.4200 allows remote attackers to execute arbitrary code via vectors involving an HTML document on the server.
4 CVE-2011-2958 79 XSS 2011-07-28 2011-08-10
4.3
None Remote Medium Not required None Partial None
Multiple cross-site scripting (XSS) vulnerabilities in Ecava IntegraXor before 3.60 (Build 4080) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Total number of vulnerabilities : 4   Page : 1 (This Page)
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.