# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
1 CVE-2014-8552 200 +Info 2014-11-26 2014-11-26
5.0
None Remote Low Not required Partial None None
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
2 CVE-2014-8551 94 Exec Code 2014-11-26 2014-11-26
10.0
None Remote Low Not required Complete Complete Complete
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
3 CVE-2014-4686 +Info 2014-07-24 2014-07-25
6.8
None Remote Medium Not required Partial Partial Partial
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.
4 CVE-2014-4685 264 +Priv 2014-07-24 2014-07-25
4.6
None Local Low Not required Partial Partial Partial
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
5 CVE-2014-4684 264 +Priv 2014-07-24 2014-07-25
6.0
None Remote Medium Single system Partial Partial Partial
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
6 CVE-2014-4683 264 +Priv 2014-07-24 2014-07-25
4.9
None Remote Medium Single system Partial Partial None
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
7 CVE-2014-4682 200 +Info 2014-07-24 2014-07-25
5.0
None Remote Low Not required Partial None None
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
8 CVE-2013-3959 200 +Info 2013-06-14 2013-06-17
4.0
None Remote Low Single system Partial None None
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
9 CVE-2013-3958 255 2013-06-14 2013-06-17
7.5
None Remote Low Not required Partial Partial Partial
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.
10 CVE-2013-3957 89 Exec Code Sql 2013-06-14 2013-06-17
7.5
None Remote Low Not required Partial Partial Partial
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
11 CVE-2013-0679 22 Dir. Trav. 2013-03-21 2013-03-22
4.0
None Remote Low Single system Partial None None
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
12 CVE-2013-0678 255 +Info 2013-03-21 2013-03-22
4.0
None Remote Low Single system Partial None None
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.
13 CVE-2013-0677 200 DoS +Info 2013-03-21 2013-03-22
5.8
None Remote Medium Not required Partial None Partial
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
14 CVE-2013-0676 264 +Info 2013-03-21 2013-03-22
4.0
None Remote Low Single system Partial None None
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
15 CVE-2013-0675 119 DoS Overflow 2013-03-21 2013-03-22
6.1
None Local Network Low Not required None None Complete
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
16 CVE-2013-0674 119 Exec Code Overflow 2013-03-21 2013-03-22
6.8
None Remote Medium Not required Partial Partial Partial
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.
17 CVE-2012-3034 200 +Info 2012-09-18 2012-09-19
4.3
None Remote Medium Not required Partial None None
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
18 CVE-2012-3032 89 Exec Code Sql 2012-09-18 2012-09-19
7.5
None Remote Low Not required Partial Partial Partial
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
19 CVE-2012-3031 79 XSS 2012-09-18 2012-09-19
4.3
None Remote Medium Not required None Partial None
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.
20 CVE-2012-3030 264 2012-09-18 2012-12-20
5.0
None Remote Low Not required Partial None None
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
21 CVE-2012-3028 352 DoS CSRF 2012-09-18 2012-09-19
6.8
None Remote Medium Not required Partial Partial Partial
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
22 CVE-2012-3015 +Priv 2012-07-26 2012-07-30
6.9
None Local Medium Not required Complete Complete Complete
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder.
Total number of vulnerabilities : 22   Page : 1 (This Page)
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.