An uninitialized pointer in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code to the software by leveraging the pointer after it is properly. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
Max CVSS
7.8
EPSS Score
0.04%
Published
2024-03-26
Updated
2024-03-26
A memory buffer vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code to the software by corrupting the memory and triggering an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
Max CVSS
7.8
EPSS Score
0.04%
Published
2024-03-26
Updated
2024-03-26
A vulnerability exists in Rockwell Automation FactoryTalk® Service Platform that allows a malicious user to obtain the service token and use it for authentication on another FTSP directory. This is due to the lack of digital signing between the FTSP service token and directory.  If exploited, a malicious user could potentially retrieve user information and modify settings without any authentication.
Max CVSS
9.8
EPSS Score
0.07%
Published
2024-01-31
Updated
2024-02-08
A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
Max CVSS
8.6
EPSS Score
0.05%
Published
2024-01-31
Updated
2024-02-08
A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product.
Max CVSS
5.3
EPSS Score
0.04%
Published
2024-03-25
Updated
2024-03-26
A heap-based memory buffer overflow vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code into the software by overstepping the memory boundaries, which triggers an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
Max CVSS
7.8
EPSS Score
0.04%
Published
2024-03-26
Updated
2024-03-26
An arbitrary code execution vulnerability in Rockwell Automation Arena Simulation could let a malicious user insert unauthorized code into the software. This is done by writing beyond the designated memory area, which causes an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
Max CVSS
7.8
EPSS Score
0.04%
Published
2024-03-26
Updated
2024-03-26
A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices.
Max CVSS
8.6
EPSS Score
0.04%
Published
2024-04-15
Updated
2024-04-16
A memory corruption vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code to the software by corrupting the memory triggering an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.
Max CVSS
7.8
EPSS Score
0.04%
Published
2024-03-26
Updated
2024-03-26
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
Max CVSS
9.1
EPSS Score
0.07%
Published
2023-10-13
Updated
2023-10-20
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
Max CVSS
8.8
EPSS Score
0.05%
Published
2023-09-12
Updated
2023-09-15
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow in the heap. potentially resulting in a complete loss of confidentiality, integrity, and availability.
Max CVSS
8.8
EPSS Score
0.24%
Published
2023-05-09
Updated
2023-11-15
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow in the heap. potentially resulting in a complete loss of confidentiality, integrity, and availability.
Max CVSS
9.8
EPSS Score
0.20%
Published
2023-05-09
Updated
2023-05-16
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow potentially resulting in a complete loss of confidentiality, integrity, and availability.
Max CVSS
9.8
EPSS Score
0.20%
Published
2023-05-09
Updated
2023-05-16
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
Max CVSS
7.1
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-12-20
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
Max CVSS
7.1
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-12-20
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
Max CVSS
5.9
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-05-15
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
Max CVSS
5.9
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-05-15
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
Max CVSS
5.9
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-05-15
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
Max CVSS
5.9
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-05-15
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
Max CVSS
5.9
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-12-20
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product A cross site scripting vulnerability was discovered that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
Max CVSS
6.5
EPSS Score
0.04%
Published
2023-05-11
Updated
2023-12-20
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
Max CVSS
7.0
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-12-20
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page.
Max CVSS
5.9
EPSS Score
0.05%
Published
2023-05-11
Updated
2023-05-15
In affected versions, a heap-based buffer over-read condition occurs when the message field indicates more data than is present in the message field in Rockwell Automation's ThinManager ThinServer.  An unauthenticated remote attacker can exploit this vulnerability to crash ThinServer.exe due to a read access violation.
Max CVSS
7.5
EPSS Score
0.06%
Published
2023-03-22
Updated
2024-01-09
226 vulnerabilities found