AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted messages, as demonstrated by an arbitrary pointer dereference attack or a buffer overflow attack.
Max CVSS
10.0
EPSS Score
47.18%
Published
2012-11-01
Updated
2013-05-21
Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.1.4621.22 use hardcoded private keys for SSL and SSH communication, which makes it easier for man-in-the-middle attackers to spoof servers and decrypt network traffic by leveraging the availability of these keys within ROS files at all customer installations.
Max CVSS
4.3
EPSS Score
0.10%
Published
2012-12-23
Updated
2013-05-21
Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which makes it easier for local users to discover passwords by reading this file.
Max CVSS
1.9
EPSS Score
0.04%
Published
2012-12-18
Updated
2012-12-19
Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.
Max CVSS
3.3
EPSS Score
0.09%
Published
2012-12-18
Updated
2013-01-29
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
Max CVSS
4.3
EPSS Score
0.22%
Published
2012-10-10
Updated
2022-02-01
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
Max CVSS
4.3
EPSS Score
0.17%
Published
2012-09-25
Updated
2022-02-01
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
Max CVSS
4.3
EPSS Score
0.22%
Published
2012-09-18
Updated
2012-09-19
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
Max CVSS
7.5
EPSS Score
0.13%
Published
2012-09-18
Updated
2012-09-19
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.
Max CVSS
4.3
EPSS Score
0.24%
Published
2012-09-18
Updated
2012-09-19
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
Max CVSS
5.0
EPSS Score
0.26%
Published
2012-09-18
Updated
2012-12-20
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
Max CVSS
6.8
EPSS Score
0.11%
Published
2012-09-18
Updated
2012-09-19
The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.
Max CVSS
7.5
EPSS Score
0.34%
Published
2012-08-06
Updated
2012-08-07
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.
Max CVSS
7.8
EPSS Score
0.67%
Published
2012-07-31
Updated
2020-04-13
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
Max CVSS
7.8
EPSS Score
0.70%
Published
2012-07-31
Updated
2020-04-13
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder.
Max CVSS
6.9
EPSS Score
0.05%
Published
2012-07-26
Updated
2012-07-30
Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls.
Max CVSS
8.5
EPSS Score
0.16%
Published
2012-08-16
Updated
2012-08-16
Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.
Max CVSS
5.8
EPSS Score
0.20%
Published
2012-06-08
Updated
2012-06-12
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.
Max CVSS
4.3
EPSS Score
0.08%
Published
2012-06-08
Updated
2012-06-12
Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.
Max CVSS
4.0
EPSS Score
0.07%
Published
2012-06-08
Updated
2012-06-12
The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack.
Max CVSS
5.5
EPSS Score
0.11%
Published
2012-06-08
Updated
2012-06-12
Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters.
Max CVSS
4.3
EPSS Score
0.20%
Published
2012-06-08
Updated
2012-06-12
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
Max CVSS
8.5
EPSS Score
1.28%
Published
2012-04-28
Updated
2022-02-01

CVE-2012-1803

Public exploit
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
Max CVSS
8.5
EPSS Score
0.98%
Published
2012-04-28
Updated
2022-02-01
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
Max CVSS
7.8
EPSS Score
6.08%
Published
2012-04-18
Updated
2012-11-20
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
Max CVSS
6.1
EPSS Score
4.89%
Published
2012-04-18
Updated
2012-11-20
44 vulnerabilities found